Installation | 5
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
13 / 28
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
• Operation in the wrong direction of rotation can destroy the machine in a short time!
Prior to start-up, ensure that the machine is operated in the right direction.
• Determine the intended direction of rotation with the arrow (stuck on or cast).
• Jog the motor briefly.
• With a phase rotation tester, check if the wiring corresponds to the correct direction of
rotation.
If the rotation of the motor must be changed:
• Switch any two of the motor phase wires.
5.5 I/O and Communication Port Schematic (Single-
phase Version Only)
Connector: D-Sub9, 9-pin, female
5 4 3
2 1
9 8 7
6
Pin Nr. Description
Signal
1
24 V Out
Power supply (max. 100 mA)
2
0 V / Ground
Ground
3
Digital Input 1
Open: Stop
Closed: Start
4
Digital Input 2*
5
Digital Input 3*
6
RS485, D+
7
RS485, D-
8
Fault relay IN
9
Fault relay OUT
*
Preset speed
DI2 / DI3
0 / 0
►
Standard speed
1 / 0
►
Boost speed
0 / 1
►
Idle speed
1 / 1
►
Boost speed
"Logic 0"
►
input voltage = 0 … 4 VDC
"Logic 1"
►
input voltage = 8 … 30 VDC
For reading status values (current, voltage,
operating hours, etc…) or parameters.
Contact NC (normally closed)
U
max
= 100 VDC / I
max
= 5 A
Communication port via Modbus (RS485):
Ask your Busch representative for more information.