5 | Installation
12 / 28
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
5.4.1 Wiring Diagram Three-Phase Motor
• Wire the mating connector (delivered loose) in accordance with the scheme below:
Mains connection (MC)
1 = Phase 1 (L1)
2 = Phase 2 (L2)
3 = Phase 3 (L3)
4 = Not used
PE = Earth
1
2
3
4
PE
• If necessary, change the connection type from star (factory default setting) to delta.
Accessing terminals:
Star connection (high voltage):
380-415 V (50 Hz), 380-480 V (60 Hz)
Factory default setting
Delta connection (low voltage):
190-220 V (50 Hz), 200-240 V (60 Hz)
W2
V2
U2
U1
W1
V1
L1
L2
L3
PE
F2
F4
F1
H1
F3
H2
W2
V2
U2
U1
W1
V1
L1
L2
L3
PE
F2
F4
F1
H1
F3
H2
F1
►
motor fan wire 1 = White
F2
►
motor fan wire 2 = Brown
F3
►
motor fan wire 3 = Green
F4
►
motor fan wire 4 = Yellow
H1
►
counter wire 1
H2
►
counter wire 2