I-Modell - 13/14 - Ausgabe 08/13 - 2354644 - BUE-0056-07EN
Electrical system
8
Switching on:
Press the On/Off key.
Select the desired operating mode and confirm with "OK".
Switching off:
Press the On/Off key.
Select the "Manual Off" operating mode and confirm with "OK". The fuel
cell switches itself off in a controlled way. This procedure can take a while.
"Shutdown procedure" appears on the display.
Automatic mode
Automatic mode starts as soon as the device is attached to the power supply.
The device monitors the battery voltage independently.
The fuel cell switches itself on automatically when the battery voltage falls
below 12.3 Volts. The battery is then charged to reach the switch-off threshold
(14.2 Volts).
When started, the device runs through a start phase lasting up to 20 minutes.
Only after this period is its full nominal power reached.
Battery protection
This function prevents the battery from discharging completely when the oper-
ating mode is set to "Off".
Battery protection is activated automatically when the battery voltage falls
below 11.2 Volts for more than 15 minutes. The "Battery protection" charge
mode ends when the voltage of 12.8 Volts is reached.
Frost protection
This mode is triggered automatically as soon as the temperature falls below
3 °C. It prevents the device from freezing.
Replacing the tank
cartridge:
Unscrew the tank cartridge connection from the empty tank cartridge.
Loosen the securing belt on the tank cartridge.
Remove empty tank cartridge from the tank cartridge holder.
After use, firmly close the cap of the tank cartridge.
Insert a new, sealed original tank cartridge into the tank cartridge holder.
Secure the tank cartridge with the securing belt.
Open cap and keep safe.
Screw tank cartridge connection onto the new tank cartridge.
In the "Main Menu > Fuel Cartridge" menu, specify the tank cartridge size
used and confirm with "OK".
8.12
Solar installation (special equipment)
X
Observe the safety instructions for methanol.
Z
Protect the solar collectors (solar module) against mechanical overload.
Z
The solar installation supplies the most current under optimal sunlight con-
ditions.
Z
Provide the solar collectors (solar module) open access to sunlight.
Z
Sunlight is greater in the open air than under trees and bridges.
Содержание I 690 G
Страница 2: ...I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Instruction manual ...
Страница 8: ...Contents 8 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN ...
Страница 18: ...18 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Safety 2 ...
Страница 120: ...120 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Gas system 7 ...
Страница 164: ...164 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Electrical system 8 Fig 177 Circuit diagram interior EBL 220 ...
Страница 254: ...254 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Wheels and tyres 13 ...
Страница 268: ...268 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Troubleshooting 14 ...
Страница 272: ...272 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Special equipment 15 ...
Страница 290: ...290 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Helpful notes 17 ...