137
I-Modell - 13/14 - Ausgabe 08/13 - 2354644 - BUE-0056-07EN
Electrical system
8
Volume of water/waste
water
The V/tank gauge is for the indication of the quantity of water or waste water.
With the V/tank gauge (Fig. 152,1), use the bottom scale. The gauge automat-
ically lights up as soon as a switch is pressed.
Displays:
Press the upper part of the rocker switch (Fig. 152,12): The volume of
water is displayed.
Press the lower part of the rocker switch (Fig. 152,12): The volume of
waste water is displayed.
8.8.2
Battery alarm for the living area battery
The red ALARM warning light (Fig. 152,14) flashes as soon as the voltage of
the living area battery falls below 11 V (measured under operation) and there
is a risk of a total discharge.
Measures:
When the battery alarm comes on, switch off the appliances and charge the
living area battery, either by mobile operation or by connection to a 230 V
power supply.
8.8.3
Digital clock/temperature gauge
Digital clock
The buttons under the gauge can be used to switch the digital clock on and off
and to set it.
Switching on:
Press the upper part of the rocker switch (Fig. 152,11): Digital clock display
is switched on. Temperature display is ready to operate.
Switching off:
Press the lower part of the rocker switch (Fig. 152,11): Digital clock display
and temperature display are switched off.
Adjusting:
Press a thin device, such as a biro, into the opening for the hour display
(Fig. 152,10) until the correct hours are displayed.
Press a thin device, such as a biro, into the opening for the minute display
(Fig. 152,9) until the correct minutes are displayed.
Z
Measure the off-load voltage preferably several hours after the previous
charging (e.g. in the morning) and not directly after a current drain.
Z
Only read the tank levels briefly. Keeping the reading option on for a long
time can damage the transducers.
Z
Total discharge damages the battery.
Z
If the battery voltage falls below 10.5 V, the battery monitor in the trans-
former/rectifier switches off all the 12 V appliances. The battery cut-off
switch is activated.
Содержание I 690 G
Страница 2: ...I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Instruction manual ...
Страница 8: ...Contents 8 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN ...
Страница 18: ...18 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Safety 2 ...
Страница 120: ...120 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Gas system 7 ...
Страница 164: ...164 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Electrical system 8 Fig 177 Circuit diagram interior EBL 220 ...
Страница 254: ...254 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Wheels and tyres 13 ...
Страница 268: ...268 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Troubleshooting 14 ...
Страница 272: ...272 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Special equipment 15 ...
Страница 290: ...290 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Helpful notes 17 ...