61
City-Car - 15/16 - Ausgabe 12/15 - 2616861 - BUE-0090-00EN
Gas system
7
7.3
DuoControl regulating system
DuoControl is a safety gas pressure regulating system with automatic
switching for a two-bottle gas system. The DuoControl regulating system auto-
matically switches the gas supply from the primary bottle to the reserve bottle
as soon as the primary bottle is either empty or no longer ready for operation.
The gas appliances may still continue operation. The DuoControl regulating
system is suitable for all commercial gas bottles with liquefied gas (propane/
butane) and a pressure of 0.6 bar to 16 bar.
The DuoControl regulating system ensures a constant gas pressure for the
gas-operated devices, no matter which gas bottle is supplying the gas.
In the case of vehicles with a DuoControl regulating system, the operation of
gas-operated devices is allowed during the journey in all of Europe.
In the event of an accident, the crash sensor in the DuoControl regulating
system will interrupt the gas flow.
The gas bottles are connected via high pressure hoses. A hose break guard
prevents gas leakage in the event of a damaged hose.
X
Use the gas pressure regulator defroster if the temperature falls below
5 °C.
X
Use only 11 kg or 5 kg gas bottles. Camping gas bottles with built-in
check valve (blue bottle with max. 2.5 or 3 kg content) are can be used
in exceptional cases with a safety valve.
X
Use the shortest possible tube lengths (150 cm max.) for external gas
bottles.
X
Never block the floor ventilation openings below the gas bottles.
Z
For gas-operated units the gas pressure must be reduced to 30 mbar.
Z
Connect gas pressure regulator complete with safety valve directly to bottle
valve.
The gas pressure regulator reduces the gas pressure in the gas bottle
down to the operating pressure of the gas devices.
Z
For filling and connecting the gas bottles in Europe the accessories shops
have corresponding Euro filling sets and Euro bottle sets.
Z
Information available at the dealers or service centre.
Z
The regulating system and the hose lines shall be changed at the latest
10 years after manufacturing date. The operator is responsible for this.
Z
Also read the manufacturer's instruction manual.
Содержание CityCar 2016
Страница 2: ...City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Instruction manual...
Страница 6: ...Contents 6 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN...
Страница 8: ...8 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Checklist before first journey of the vehicle...
Страница 12: ...12 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Introduction 1...
Страница 30: ...30 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Before the journey 3...
Страница 42: ...42 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Pitching the motorhome 5...
Страница 66: ...66 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Gas system 7...
Страница 98: ...98 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Appliances 9...
Страница 122: ...122 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Care 11...
Страница 142: ...142 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Special equipment 15...
Страница 144: ...144 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Technical data 16...