190
Premio/Averso - 13/14 - Ausgabe 09/13 - 2354619 - BUE-0048-12EN
Troubleshooting
14
14.6
Gas system
Interior lighting does no
longer work correctly
Bulb is defective
Unscrew cover of the rel-
evant light, replace bulb.
Note volts and watts
specifications
Fuse on the power sup-
ply unit is defective
Replace the fuse on the
power supply unit
No voltage from the living
area battery (if there is
one)
Living area battery is dis-
charged
Charge living area bat-
tery immediately
Z
Total discharge
damages the
battery.
If the vehicle is to be laid
up for a long period, fully
charge the living area
battery beforehand
Extractor hood does not
work
230 V automatic circuit
breaker switched off
Switch on 230 V auto-
matic circuit breaker
Power supply unit is de-
fective
Contact customer service
Fuse on the power sup-
ply unit is defective
Replace fuse
Extractor hood defective
Contact customer service
Air conditioning unit can-
not be switched on or off
230 V automatic circuit
breaker has triggered
Switch on 230 V auto-
matic circuit breaker
Remote control battery is
empty
Change remote control
battery
X
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X
Have the defective gas system repaired by an authorised specialist
workshop.
Fault
Cause
Remedy
No gas
Gas bottle is empty
Change gas bottle
Gas isolator tap closed
Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for bu-
tane gas)
Wait for higher external
temperatures
Built-in appliance is de-
fective
Contact customer service
Fault
Cause
Remedy
Содержание Averso
Страница 2: ...Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Instruction manual ...
Страница 10: ...10 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Introduction 1 ...
Страница 34: ...34 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Before the journey 3 ...
Страница 90: ...90 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Gas system 7 ...
Страница 152: ...152 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Sanitary fittings 10 ...
Страница 164: ...164 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Care 11 ...
Страница 224: ...Index 224 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN ...