Electrical system
8
8.6.8
Switch for water pump
The water pump can be turned on and off using the water pump button
(Fig. 118,10).
Switching on:
Press the water pump button (Fig. 118,10). The symbol lights up.
Switching off:
Press the water pump button (Fig. 118,10). The symbol goes out.
8.7
Fuel cell (EFOY) (special equipment)
Z
The switch status of the water pump is saved when the 12 V power supply
is switched off. This means: If the water pump was switched on when the
12 V power supply was switched off, it is also switched on after the 12 V
power supply is switched back on.
X
Methanol is toxic. Avoid inhaling, swallowing or any contact with the skin
or the eyes.
X
If methanol leaks, there is a danger of fire. Keep away from sources of
ignition and ventilate well. Methanol evaporates without residue.
X
Always adhere to the safety data sheet from the manufacturer.
X
The fuel cell must not be opened.
X
The tank cartridge must not be opened with force or refilled.
X
Keep fuel cell and tank cartridges – including empty or half-empty tank
cartridges – out of the reach of children.
X
When used in vehicles, the fuel cell and the tank cartridges must be
secured to avoid accidents.
Z
Do not store the fuel cell at temperatures above 45 °C or below 1 °C.
Z
Do not operate the fuel cell at temperatures above 40 °C or below -20 °C.
Z
When the appliance is connected to an intact battery, the frost protection
switches on automatically if the ambient temperature drops below 3 °C,
even if the fuel cell is switched off. Therefore always connect a full tank car-
tridge and a sufficiently charged battery, if it is stored below 3 °C.
Z
If the fuel cell freezes despite taking all precautions, leave the appliance to
defrost at room temperature for approx. 24 hours in a switched off state.
Then it can be used again.
Z
Do not cover the ventilation holes on the fuel cell. Danger of overheating!
Z
The fuel cell is not waterproof. Clean casing only with a slightly damp cloth
and ensure that water does not enter the device.
Z
The minimum running time of the fuel cell is 30 minutes. If the On/Off key
is pressed during this period, the fuel cell only shuts down when this min-
imum operating time expires. The LEDs light up on during this time.
Z
Further information can be obtained in the instruction manual for the fuel
cell.
Содержание A 650
Страница 2: ...A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Instruction manual ...
Страница 34: ...34 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Before the journey 3 ...
Страница 52: ...52 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Pitching the motorhome 5 ...
Страница 96: ...96 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Gas system 7 ...
Страница 127: ...127 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Electrical system 8 Fig 136 Circuit diagram interior EBL 220 ...
Страница 132: ...132 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Electrical system 8 ...
Страница 164: ...164 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Appliances 9 ...
Страница 184: ...184 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Sanitary fittings 10 ...
Страница 196: ...196 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Care 11 ...
Страница 210: ...210 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Maintenance 12 ...
Страница 230: ...230 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Troubleshooting 14 ...
Страница 234: ...234 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Special equipment 15 ...
Страница 238: ...238 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Technical data 16 ...
Страница 250: ...250 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Helpful notes 17 ...