3.9.1. Painted Metal Surfaces 

These surfaces should be dusted regularly and any marks removed with a soft damp cloth. 
 

3.9.2. Care of Ceramic Backs 

The ceramic fireback on this appliance must NOT be sprayed with any type of solvent-based 
high temperature paint. 
 
The  very  high  temperatures  produced  within  the  appliance  will  cause  the  paint  to  bubble 
and/or burn off rendering the fireback looking unsightly. 
 
Minor  surface  scuffs  may  be  treated  using  a  water  based  touch  up  stain  available  at  Burley 
Magiglo fire retailers. 
 

 

Extreme care should be taken when handling and installing products containing 
ceramic interiors, so as not to cause damage.

 

 
 
 

Содержание Surefire FCC 16

Страница 1: ...ructions MUST BE LEFT WITH THE USER SUREFIRE Fuel Effect Options Coal Effect Control Options Slide Control with Convection Fan Model No FCC 16 Inset Coal Effect For use on Natural Gas only G20 at a su...

Страница 2: ...nt of a defect in materials or workmanship occurring within one year of purchase Burley Magiglo will arrange to repair or replace the item free of charge Any claims under this warranty must be made th...

Страница 3: ...sions 15 4 4 Technical Data 16 4 5 Mantels Combustible Shelves 16 4 6 Appliance Location 16 4 6 1 Floor Level and Raised Fireplace Openings 17 4 7 Ventilation 18 4 8 Contents Checklist 18 4 9 Installa...

Страница 4: ...ts so much heat this vapour condenses As the fire warms up the condensation will evaporate Do not be surprised if you see small amounts of steam exiting at the bottom edges of the glass Burning the Ga...

Страница 5: ...e of the Surefire is a baffle which closes the flue when not in use keeping the warm air in your house This massing saving is not included in the Surefire s 94 7 efficiency rating it is in addition to...

Страница 6: ...aration of Conformity to indicate compliance to I S 813 2 It is important for correct combustion of this fire that the imitation fuel is placed in accordance with the instructions given in this bookle...

Страница 7: ...e 2 Plug the power supply transformer unit into an adjacent socket and route the cable to the appliance and insert the DC plug into the socket behind the fret on the left hand side of the appliance Th...

Страница 8: ...free air in ash pan cover Figure 1 Fire Front Specification Height to Centre A Maximum 9 Inches 23cm Minimum 6 Inches 15cm Ash Pan Cover Height B Maximum 3 5 Inches 9cm Minimum 2 5 Inches 6 4cm Ash P...

Страница 9: ...tive switch and will start automatically as the fire warms up and will switch off as the fire cools It may continue to run after the fire is turned off as the fire will take some time to cool down If...

Страница 10: ...silicate fibres Excessive exposure to this material may cause irritation to eyes skin and respiratory tract Therefore during installation and servicing we recommend that you use a HEPA filtered vacuu...

Страница 11: ...with the curved edges upwards and the black faces visible Position the rear burner ceramic in position behind the rear burner flange Place the front burner ceramic in its support in front of the burne...

Страница 12: ...uble glazing draught proofing fitting extractor fans etc are carried out to the property it is essential to carry out a spillage test on the fire to ensure that the flue is still operating satisfactor...

Страница 13: ...censed landfill sites Black Painted Surfaces These surfaces should be dusted regularly and any marks removed with a soft damp cloth Brass or Chrome Surfaces These surfaces should be cleaned with a pro...

Страница 14: ...e of solvent based high temperature paint The very high temperatures produced within the appliance will cause the paint to bubble and or burn off rendering the fireback looking unsightly Minor surface...

Страница 15: ...dings Available from Institute of Gas Engineers managers BS5871 2 2005 Part 2 Inset live fuel effect gas fires of heat input not exceeding 15kW BS EN 1856 Chimneys Requirements for metal chimneys Syst...

Страница 16: ...information For installation in IE refer to the current edition of I S 813 Domestic Gas Installations A faulty flue or chimney may result in smoke and fumes entering the room The flue should be sound...

Страница 17: ...Page 15 4 3 General Dimensions...

Страница 18: ...discolour in time The temperature rating of the surround should be checked before use We recommend a fire surround with a minimum 150 degrees Celsius rating 4 6 Appliance Location In all installations...

Страница 19: ...penings OH 560mm OW 405mm OD 235mm min Raised Installation HD HF Height of Hearth from Floor at least 225mm Table 1 Hearth Construction The hearth material must be non combustible and a minimum of 12m...

Страница 20: ...cient ventilation is available 2 Any purpose provided ventilation must be checked periodically to ensure it is free from obstructions 3 When fitting the fire in Northern Ireland NI purpose provided ve...

Страница 21: ...crews holding the upper glass clamp remove the glass panel Store the louvre and glass panels in a safe place during the installation process 4 9 2 Installation of the Firebox 1 Mark out drill plug and...

Страница 22: ...Page 20...

Страница 23: ...the fret on the left hand side of the appliance The cable should be installed through a conduit sufficiently large to accommodate the DC plug so that replacement of the power supply transformer unit i...

Страница 24: ...ard Place the two pegged coals in position 4 9 6 Fitting the glass panel Refit the glass panel by seating it centrally behind the lower clamp and securing by fixing the upper clamp in position with th...

Страница 25: ...nsure that the pressure at the pressure test point is between 19 and 21 mbs Alternatively the information is given on the data badge of the appliance 6 If the correct pressure cannot be achieved then...

Страница 26: ...set the restrictor flap in the fully open position by moving the thermostat operating arm limit screw from the upper hole to the lower hole in its bracket Before screwing the limit screw home push th...

Страница 27: ...Check that the electrode sparks across the gap when the slider lever is pushed to the left 5 Use a vacuum cleaner to remove any fluff or lint on the base of the combustion chamber 6 Undo the two secu...

Страница 28: ...dvice This product may use Components Coals Ceramic backs containing Refractory Ceramic Fibres RCF which are man made vitreous silicate fibres Excessive exposure to this material may cause irritation...

Страница 29: ...ly but pilot will not light a No gas supply Check isolation valve supply d Spark Generator Battery Flat Replace Battery b Pilot jet blocked Replace pilot assembly Pilot lights but goes out when contro...

Страница 30: ...he pilot assembly i e thermocouple electrode jet or burner becomes faulty the whole pilot assembly will need changing NOTE For any spare parts that are required please contact your You will either nee...