18
Installation
7
InSTAllATIon
7.1
Safety instructions
notiCe
Risk of damage to the product due to non-conforming installation.
•
The electrical and fluidic installations can only be carried out by qualified and skilled staff with the appropriate
tools.
•
Respect the installation instructions for the system.
notiCe
Risk of damage to the product due to the power supply
•
Shut down and isolate the electrical power source before carrying out work on the system.
notiCe
Risk of damage to the product due to the environment
•
Protect the product against electromagnetic interference, ultraviolet rays and, when installed outdoors,
the effects of the climatic conditions.
7.2
Mounting the product on the backplane
The product is plugged in the backplane of the Type 8905 system.
4
3
3
Backplane
1. Dry the surface of the back-
plane that will be in contact
with the product.
2. Dry the surface of the product.
3. While the push-button is
pushed, turn the bayonet lever
to the right, on the unlocked
position,
. Do not push
the lever to the maintenance
position.
4. Insert the two adaptation pins
in their holes and then plug the
product in the backplane.
5. While the push-button is
pushed, turn the bayonet
lever to the left, on the locked
position, .
Fig. 3:
Mounting a product on the backplane of the system
English
Type MS01
Содержание Type MS01
Страница 1: ...Operating Instructions Type MS01 pH sensor cube...
Страница 86: ...86 English Type MS01...
Страница 87: ......