2-20 NovaScale 3005 Series - Installation and User's Guide
# LED Color
State
Description
On
System is ON
Blinking
System is being powered OFF
F Power
LED
Green
Off
System is OFF
On/Off
This LED is used to identify one server
among others by toggling on/off the
identification switch.
G Identification
LED Blue
Blinking
CMOS clear or FWH recovery mode.
On
Critical, non-recoverable power fault has
been detected.
Blinking
Non-critical power fault has been
detected.
H Power Fault LED Orange
Off
No power fault has been detected
On
Critical, non-recoverable cooling fault
has been detected.
Blinking
(1 Hz)
Non-critical cooling fault has been
detected.
I Cooling Fault LED Orange
Off
No cooling fault has been detected
On
Critical, non-recoverable fault other than
power or cooling fault has been
detected.
Blinking
Non-critical fault other than power or
cooling fault has been detected.
J General Fault LED Orange
Off
No general fault has been detected
Table 2-7. Control panel LED states
Содержание NovaScale 3005 Series
Страница 1: ...NovaScale 3005 Series Installation and User s Guide NOVASCALE REFERENCE 86 A1 02ET 05...
Страница 2: ......
Страница 18: ...xvi Bull NovaScale 3005 Series Installation and User s Guide...
Страница 23: ...Delivery 1 5 Figure 1 2 Location of Warning Labels on NovaScale 3025 3045 server rear...
Страница 54: ...2 30 NovaScale 3005 Series Installation and User s Guide...
Страница 78: ...A 4 Bull NovaScale 3005 Series Installation and User s Guide...
Страница 142: ...C 40 Bull NovaScale 3005 Series Installation and User s Guide...
Страница 157: ......
Страница 158: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE No 86 A1 02ET 05...