Chapter
2.
Maintenance
Analysis
Procedures
for
Service
Representatives
DANGER
To
prevent
a
possible
electrical
shock
from
touching
two
surfaces
with
different
electrical
grounds,
use
one
hand,
when
possible,
to
connect
or
disconnect
signal
cables.
(RSFTD004)
DANGER
An
electrical
outlet
that
is
not
correctly
wired
could
place
hazardous
voltage
on
metal
parts
of
the
system
or
the
products
that
attach
to
the
system.
It
is
the
customer’s
responsibility
to
ensure
that
the
outlet
is
correctly
wired
and
grounded
to
prevent
an
electrical
shock.
(RSFTD201)
CAUTION:
Ensure
that
all
rack-mounted
units
are
fastened
in
the
rack
frame.
Do
not
extend
or
exchange
any
rack-mounted
units
when
the
stabilizer
is
not
installed.
(RSFTC222)
CAUTION:
When
the
unit
is
extended,
its
weight
can
turn
over
a
rack
that
is
not
steady.
Before
you
pull
the
unit
out
of
the
rack,
ensure
that
a
rack
stabilizer
is
attached
to
the
bottom
front
of
the
rack.
Do
not
pull
out
more
than
one
unit
at
a
time.
The
rack
can
turn
over
if
you
pull
out
more
than
one
unit
at
a
time.
(RSFTC224)
Purpose
of
the
MAPs
Maintenance
analysis
procedures
(MAPs)
are
used
to
check
the:
Power
switch
Power
supply
Power
distribution
cable
SAS
cables
DVD
cable
Fan
Configuration
Drives
VPD
cable
Power
cord
Power
source
The
media
drawer
includes
several
LED’s
that
indicate
the
presence
and
source
of
a
fault,
and
has
the
capability
to
report
faults
to
the
operating
system.
These
should
be
the
primary
sources
for
fault
identification.
If
these
prove
insufficient
then
MAPs
should
be
used,
especially
to
identify
faulty
cables
or
cable
connections.
If
a
problem
is
detected,
the
procedure
isolates
the
problem
to
the
failing
field
replaceable
unit
(FRU).
For
instructions
about
removing
or
replacing
a
FRU,
refer
to
Chapter
3,
“Removal
and
Replacement
Procedures,”
on
page
19
Note:
Service
actions
involving
the
removal
of
the
enclosure
cover
must
be
performed
by
an
IBM
authorized
service
representative.
©
Copyright
IBM
Corp.
2007
7
Содержание ESCALA 7214
Страница 1: ...7214 Model 1U2 Storage Device Enclosure Service Guide ESCALA REFERENCE 86 A1 69EW 00...
Страница 2: ......
Страница 6: ...iv 7214 Storage Device Enclosure Service Guide...
Страница 14: ...xii 7214 Storage Device Enclosure Service Guide...
Страница 34: ...18 7214 Storage Device Enclosure Service Guide...
Страница 50: ...34 7214 Storage Device Enclosure Service Guide...
Страница 54: ...38 7214 Storage Device Enclosure Service Guide...
Страница 56: ...40 7214 Storage Device Enclosure Service Guide...
Страница 60: ...44 7214 Storage Device Enclosure Service Guide...
Страница 66: ...50 7214 Storage Device Enclosure Service Guide...
Страница 69: ......
Страница 70: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 69EW 00...