4-60
2006 Buell Lightning: Fuel System
HOME
TROUBLE CODE 16
4.20
GENERAL
Battery Voltage
A Code 16 will set if the ECM detects battery positive voltage
less than 6 volts or greater than 20 volts.
●
A low voltage condition typically occurs during activation
of the starter or generally indicates loose wire connec-
tions.
●
A high voltage condition is usually caused by a faulty
voltage regulator.
DIAGNOSTICS
Diagnostic Notes
The reference numbers below correlate with the circled num-
bers on the Code 16 flow charts.
1.
The ECM is monitoring voltage at ECM connector [10]
(black) Terminal 1. Connect BREAKOUT BOX (Part No.
HD-42682) to ECM. See
4.6 BREAKOUT BOX
.
2.
This checks for voltage drops in the ECM power circuit. If
a significant voltage drop is not present, condition may
be caused by excessive starter current draw.
Figure 4-42. Fuse Block and Electrical Relays
(XB12Ss)
12150
Figure 4-43. Fuse Block and Electrical Relays (Typical)
1.
Fuse block
2.
Key switch relay
3.
Ignition relay
4.
Start relay
1
2
4
3
10658
Содержание 2006LIGHTNING MODELS
Страница 2: ......
Страница 12: ...HOME ...
Страница 34: ...B 22 2006 Buell Lightning Electrical HOME 2006 Lightning Lighting Circuit 2006 Lightning Lighting Circuit ...
Страница 46: ...D 2 2006 Buell Lightning Appendix D HOME Figure D 2 Rear Brake Systems Top View b1115xbsx ...
Страница 47: ...2006 Buell Lightning Appendix D D 3 HOME Figure D 3 Rear Brake Systems Left Side View b1116xcsx ...
Страница 58: ...HOME NOTES ...
Страница 68: ......
Страница 98: ...HOME NOTES ...
Страница 124: ...HOME NOTES ...
Страница 126: ......
Страница 180: ...HOME NOTES ...
Страница 234: ......
Страница 340: ...HOME NOTES ...
Страница 344: ...HOME NOTES ...
Страница 384: ...HOME NOTES ...
Страница 474: ......
Страница 496: ...HOME NOTES ...
Страница 498: ......
Страница 554: ...6 56 2006 Buell Lightning Drive Transmission HOME NOTES ...
Страница 556: ......
Страница 638: ......