Header connection
8
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
38
Fitting the air vent
z
Firmly screw threaded fitting (Fig. 60,
Item 6
) and
double threaded fitting (Fig. 60,
Item 4
) into air pot
(O-ring gasket).
z
Push air pot (Fig. 60,
Item 5
) and fitting onto collector
connection and secure with clip.
z
Connect header pipe to the compression fitting
(15 mm) (Fig. 60,
Item 2
).
8.4
Connecting two arrays
If connecting two collector arrays (Fig. 61,
Item 1
) you
will need a second connection kit.
z
Fit individual parts as described in Chapter 8.2 "Ven-
ting through pressure filling".
z
Make on-site connection between collector arrays
using copper pipe.
Fig. 60
Connecting the air vent
Item 1:
Connector clip
Item 2:
Union nut for 15 mm compression fitting
Item 3:
Olive
Item 4:
Double threaded fitting with O-ring
Item 5:
Air pot
Item 6:
Threaded fitting
63043969.05-1.SD
63043969.05-1.SD
2
1
3
4
5
6
Fig. 61
Two collector arrays, one behind the other
63043969.06-1.SD
63043969.06-1.SD
1
1