Installing flat roof and wall mounting supports
5
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
19
5.1.2 Version with auxiliary brace (accessory)
For greater loads, an auxiliary brace (and additional pro-
file rails, page 27) is required for portrait installation for
the second and all further collectors (Fig. 22). This ver-
sion can be used for the following loads:
—
Building height max. 100 m (installation height)
—
max. 3.8 kN/m² wind or snow load
Fig. 22
Auxiliary braces for 3 portrait collectors
63043970.14-1.SD
63043970.14-1.SD
63043970.14-1.SD
980
980
980
190
190
USER NOTE
For landscape installation, a max. building
height of 100 m and a max. wind or snow
lo
ad
of 3.8 kN/m² are permitted using the
basic version (Fig. 21, provided that an ad-
ditional rail is fitted, page 27).