Installing flat roof and wall mounting supports
5
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
21
For landscape installation, 3 collector braces must be fit-
ted for each collector (Fig. 24).
5.2.2 Version for maximum loads (accessory,
Fig. 25)
For greater loads, ropes (page 23) and additional rails
(page 27) are also required. This version can be used
for the following loads:
—
Building height max. 100 m (installation height)
—
max. 3.8 kN/m ²wind or
snow load
Fig. 24
Basic version for 2 landscape collectors
63043970.14-1.SD
63043970.16-1.SD
63043970.16-1.SD
980
980
135
980
980
USER NOTE
Landscape installation can be carried out
using only the auxiliary brace (accessory).
Fig. 25
Version for maximum loads, 3 portrait collectors
63043970.14-1.SD
63043970.14-1.SD
63043970.14-1.SD
980
980
980
190
190
USER NOTE
For distances between the landscape coll-
ector braces for maximum loads, refer to
Fig. 24.