Before installation
4
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
16
4.7.2 Estimating your space requirements
Allow sufficient installation space for the different forms
of installation (landscape, portrait).
These dimensions (Tab. 5 and Tab. 6) relate to the roof
surface area which must be available.
The quoted dimensions are simply the width of the coll-
ector array. In addition, allow at least 0.5 m on either
side of the collector array for pipework.
Fig. 15
Distance from the edge of the roof
>1 m
>1 m
63043970.41-1.SD
63043970.41-1.SD
CAUTION!
SYSTEM DAMAGE
through wind, eddies and pressure peaks
around the roof edges.
z
Before commencing the installation,
ensure that at least one metre is allo-
wed between the flat roof supports and
the edge of the roof (Fig. 15).
Fig. 16
Space requirements — collector array — portrait
version
63043970.10-1.SD
63043970.10-1.SD
A
B
Space requirements for portrait collectors:
Space requirements for landscape collectors:
Number
of collectors
Dimension
A
Angle of
inclination
Dimension
B
Number
of collectors
Dimension
A
Angle of
inclination
Dimension
B
2
2.34 m
25°
1.84 m
2
4.18 m
25°
1.06 m
3
3.51 m
30°
1.75 m
3
6.28 m
30°
1.02 m
4
4.68 m
35°
1.68 m
4
8.38 m
35°
0.96 m
5
5.85 m
40°
1.58 m
5
10.48 m
40°
0.91 m
6
7.02 m
45°
1.48 m
6
12.58 m
45°
0.85 m
7
8.19 m
50°
1.48 m
7
14.68 m
50°
0.85 m
8
9.36 m
55°
1.48 m
8
16.78 m
55°
0.85 m
9
10.53 m
60°
1.48 m
9
18.88 m
60°
0.85 m
10
11.70 m
10
20.98 m
Tab. 5