Extended functions
7
Logamatic 4321/4322 - Technical specifications are subject to change without prior notice.
48
7.20 Room temperature matching
The factory setting is 0 °F (0 °C). The possible setting range is +9 °F to
-9 °F (+5 °C to -5 °C).
Example:
Displayed room temperature 72 °F (22 °C), actual room temperature
73.5 °F (22.5 °C).
z
Open flap.
Simultaneously press and then release "Display" and "Temp".
The display shows "CALIBRATING MEC".
Hold down "Temp" and turn the dial to the desired value (here: "+1.0°F"
(+0.5°C)).
The display shows the set value.
Release "Temp" to save your input.
Press "Back" to return to the permanent display.
The display shows the corrected temperature (73.5 °F (22.5 °C)).
USER NOTE
This function is only available if the MEC2 is installed within the living space. If
the room temperature shown on the display varies from the actual temperature
measured with a thermometer, the display value can be adjusted using
"CALIBRATING MEC".
+
CALIBRATING MEC
correction
room temperature
0.0°F
+
CALIBRATING MEC
correction
room temperature
+1.0°F