Offset for heating circuit 1
-9 – +9°F (-5°C – +5°C)
0°F (0°C)
Offset for heating circuit 2
-9 – +9°F (-5°C – +5°C)
0°F (0°C)
DHW priority
ON/OFF
ON
Maximum heating circuit
temperature for heating circuit 2
(PERIM HTG)
68 – 140°F (20°C – 60°C)
PERIM HTG
194°F (90°C)
Maximum heating circuit
temperature for heating circuit 2
(FLOOR HTG)
68 – 194°F (20°C – 90°C)
FLOOR HTG
113°F (45°C)
Solar function
ON/OFF
ON
MAX-SL SR
140 – 194°F (60°C – 90°C)
167°F (75°C)
MIN-SL SR
86 – 130°F (30°C – 54°C)/OFF
OFF
DHW PROD
ON/OFF
ON
DHW recirculation pump
OFF/1/2/3/4/5/6/ON
2
Time
-30 seconds/day – +30 seconds/day
0 seconds/day
Input range
Factory setting
Setting
Logamatic 2107 controls - We reserve the right to make any changes due to technical modifications.
5
9
19
Operating values at the service level/setup report