KTF/100HPS Troubleshooting and Maintenance
KTF/100HPS
- 4.3 -
Faults
Causes
Solutions
OVERFLOW inc
or
OVERFLOW dec
displayed on KTF
display
1) Incompatibility between the KTF
programming and the number of
increments/decrements
generated by the machine
program
1) Check the KTF programming, in particular the INC-
DEC tension parameters in
P1
, and the machine
program
(check the number of
increments/decrements required).
The KTF device does
not communicate with
SMART-KTF 2000
terminal
1) The identification code of KTF
device is not correct
2) Failure on SMART-KTF 2000
terminal
3) Wiring problem
1) Check that the parameter corresponding to the
identification number
(parameter
P3.4
)
is correct; if
necessary carry out the numbering procedure using
the SMART-KTF 2000 terminal or set directly the
identification code on KTF device
(parameter
P3.4
)
.
2) Check the correct operation of SMART-KTF 2000
terminal using the numbering procedure described
in the SMART KTF 2000 manual.
3) Check the wiring starting from "SMART- IN"
connector on KTF/PW4 power supply and on
SMART-KTF 2000 terminal.
!
If the fault is not included in this table, please contact your local BTSR reseller, giving a detailed
description of the kind of fault and the conditions in which it occurred. In the case where the BTSR
Technical Service intervention would be required, before calling it is suggested to take note of the
code printed on the faulty device, as this information will make diagnoses for the BTSR technicians
easier.
Example:
Device code:
KTF/100HPS V2S101 1101 A001412