July 2013 © British Telecommunications plc 2013
Page 29
The web console “quick start” page in Fig. 17 is shown populated with the factory defaults.
Clicking on the “Save Config” button, at the bottom of the screen, sends the configuration to
the unit and then restarts the unit.
Definition of quick start settings
Account Information.
Account number: Default = 0. This field can optionally be populated with the TA number
of the device. Can be used to auto populate SID on the account at commission time.
Agency ID: Default = 0. Normally always set to 0
Management Port: Default = 9000. Always set to 9000.
Interface combination.
Interface select: Default = Wi Dialup. This field enables the unit’s
communication paths. Use “Wi Dialup” for “Secure 2 & 3” or “Wi
Wireless” for “Secure IP”
Wireline settings (IP path details)
Server 1. Default 62.239.139.2 the address of the B side ESP servers.
Server 2. Default 62.239.139.130 the address of the A side ESP servers.
Server 3. Default = blank.
Server 4. Default = blank.
Tunnel Server port. Default = 443. The IP port used to establish the IP path tunnel. Can
be set to alternative port 10443 if required by some IT system managers (see F5)
Proxy server settings. The following settings are only required where direct Outgoing
access is not available on IP port 443 or 10443, and the IT system manager requires
all outgoing traffic to be routed via a proxy server.
o
Proxy IP:Port : Default = blank. Can be populated with the IP address and port
of a proxy server if required by some IT system managers.
o
Proxy Auth type: Default = None. Can be set to None, basic or NTLM if required
by some IT system managers.
o
Proxy User: Default = blank. Username for a Proxy server where required.
o
Password: Default = blank. Password for the Proxy server where required.
LAN settings
DHCP. Default = ticked. The unit will automatically obtain its IP addressing details from
a DHCP server on the LAN. Untick to turn off DHCP where static IP addressing is
required by the IT system manager.
IP Address: Default = Last used IP address e.g. 192.168.1.15. Can be set to a static
IP address where required by the IT system manager. Auto populated if DHCP is
enabled.