The status and log screen shows the current system status, and access to the unit’s event
history.
The Event log history is extensive and will go back further than the last unit re-start. (i.e. the
event history is stored in flash memory and not cleared by loss of power). The event log will
store a minimum of 1025 events.
Events that are generated while the time on the unit is not set, i.e. after the unit has been
powered up but before the unit has communicated with the ESP to obtain the correct time, are
time stamped with the pseudo time and date in the year 2000 as per Fig. 18.
Note that events logged while the unit’s time has been synchronised will use Greenwich Mean
Time (GMT).
When a PSTN call is attempted and fails to establish, a “Fail to communicate” event is logged
in this local log. For further debugging there is a “Device number” associated. i.e. Device 0/2
means the unit failed to dial the second telephone number.
Other typical messages that may appear in the log.
Telephone line restore. Device 0
PSTN has successfully dialled up after a fail.
Fail to communicate. Device 0/1
PSTN call to Telephone number 1 failed
Fail to communicate. Device 0/2
PSTN call to telephone number 2 failed
Panel upload Download.
Remote access to the alarm panel can be achieved using the BT Redcare UDL facility.
Contact your BT Redcare representative for details of accessing the BT Redcare UDL servers.