43
Troubleshooting
23.0
Troubleshooting
Problem:
No output
Solution:
Is the MUTE switch depressed?
Is the mains power on? (
See section 8.0
)
Check the connections. See Fuse failure (below).
Do you have an input signal?
Is the SIGNAL LED on?
Check the input and output connections (
See sections 9.0 & 10.0
).
Are the power amplifiers switched on?
Problem:
Excessive Hum, Intermittent sound
Solution:
First check the connections on your input and output plugs (
See sections 9.0 &
10.0
). Unshielded cables, improperly wired connectors and damaged cables
are the most common cause of sound system hums and buzzes. Then
refer to
sections 8.0
.
Problem:
Blown fuse
Solution:
The mains supply fuse is unlikely to blow without an electronic fault being
present (
See section 8.0
). If the fuse blows again at switch on or after a short
interval, switch off the unit and arrange for servicing. The internal DC fuses
will only blow in the event of major fault condition. If they are visibly blown,
DO NOT OPERATE THE UNIT
. Return it to be serviced.
Содержание FDS 360