34
Table 15 – Gas Valve Outlet Pressure for Gas Heat Values at
Altitude -- 60,000
Tabulated Data Based on 60,000 BTUH Input for 0-ft (0m) to
5400-ft (1646-M) above
sea level
ALTITUDE
RANGE
AVG. GAS
SPECIFIC GRAVITY OF
NATURAL GAS
HEAT VALUE
0.58
0.60
0.62
0.64
AT ALTITUDE
Gas Valve Outlet Pressure
(in. W.C.)
ft (m)
(Btu/cu ft)
U.
S
.A.
0
900
3.0
3.1
3.2
3.3
925
2.8
2.9
3.0
3.1
(0)
950
2.7
2.8
2.9
3.0
975
2.6
2.6
2.7
2.8
to
1000
2.4
2.5
2.6
2.7
1025
2.3
2.4
2.5
2.5
2000
1050
2.2
2.3
2.4
2.4
(610)
1075
2.1
2.2
2.2
2.3
1100
2.0
2.1
2.1
2.2
U.
S
.A.
2001
800
3.2
3.3
3.5
3.6
825
3.0
3.1
3.3
3.4
(611)
850
2.9
3.0
3.1
3.2
875
2.7
2.8
2.9
3.0
to
900
2.6
2.6
2.7
2.8
925
2.4
2.5
2.6
2.7
3000
950
2.3
2.4
2.5
2.5
(914)
975
2.2
2.3
2.3
2.4
1000
2.1
2.1
2.2
2.3
U.
S
.A.
On
ly
3001
775
3.2
3.3
3.4
3.5
800
3.0
3.1
3.2
3.3
825
2.8
2.9
3.0
3.1
(915)
850
2.6
2.7
2.8
2.9
to
875
2.5
2.6
2.7
2.8
900
2.4
2.4
2.5
2.6
4000
925
2.2
2.3
2.4
2.5
(1219)
950
2.1
2.2
2.3
2.3
975
2.0
2.1
2.2
2.2
1000
1.9
2.0
2.0
2.1
U.
S
.A.
On
ly
4001
750
3.1
3.2
3.4
3.5
775
2.9
3.0
3.1
3.2
800
2.8
2.9
2.9
3.0
(1220)
825
2.6
2.7
2.8
2.9
850
2.4
2.5
2.6
2.7
to
875
2.3
2.4
2.5
2.5
900
2.2
2.3
2.3
2.4
5000
925
2.1
2.1
2.2
2.3
(1524)
950
2.0
2.0
2.1
2.2
975
1.9
1.9
2.0
2.0
1000
1.8
1.8
1.9
1.9
U.
S
.A
.
On
ly
725
2.8
2.9
3.0
3.0
750
2.6
2.7
2.8
2.8
5001
775
2.4
2.5
2.6
2.7
(1524)
800
2.3
2.3
2.4
2.5
825
2.1
2.2
2.3
2.3
to
850
2.0
2.1
2.1
2.2
875
1.9
1.9
2.0
2.1
5400
900
1.8
1.8
1.9
2.0
(1646)
925
1.8
1.8
1.8
1.9
950
1.8
1.8
1.8
1.8
975
1.8
1.8
1.8
1.8
1000
1.8
1.8
1.8
1.8
Table 16 – Gas Valve Outlet Pressure for Gas Heat Values at
Altitude -- 80,000
Tabulated Data Based on 80,000 BTUH Input, for 0-ft (0-m) to
5400-ft (1646-M) ab
ove sea level
ALTITUDE
RANGE
AVG. GAS
SPECIFIC GRAVITY OF
NATURAL GAS
HEAT VALUE
0.58
0.60
0.62
0.64
AT ALTITUDE
Gas Valve Outlet Pressure
(in. W.C.)
ft (m)
(Btu/cu ft)
U.
S
.A.
900
2.8
2.9
3.0
3.1
0
925
2.6
2.7
2.8
2.9
(0)
950
2.5
2.6
2.7
2.8
975
2.4
2.5
2.5
2.6
to
1000
2.3
2.3
2.4
2.5
1025
2.1
2.2
2.3
2.4
2000
1050
2.0
2.1
2.2
2.3
(610)
1075
1.9
2.0
2.1
2.1
1100
1.9
1.9
2.0
2.1
U.
S
.A.
800
3.0
3.1
3.1
3.1
2001
825
2.8
2.9
3.0
3.1
(611)
850
2.7
2.8
2.9
3.0
875
2.5
2.6
2.7
2.8
to
900
2.4
2.5
2.5
2.6
925
2.2
2.3
2.4
2.5
3000
950
2.1
2.2
2.3
2.4
(914)
975
2.0
2.1
2.2
2.2
1000
1.9
2.0
2.1
2.1
U.
S
.A.
On
ly
775
3.0
3.1
3.1
3.1
800
2.8
2.9
3.0
3.1
3001
825
2.6
2.7
2.8
2.9
(915)
850
2.5
2.6
2.6
2.7
to
875
2.3
2.4
2.5
2.6
900
2.2
2.3
2.3
2.4
4000
925
2.1
2.1
2.2
2.3
(1219)
950
2.0
2.0
2.1
2.2
975
1.9
1.9
2.0
2.1
1000
1.8
1.8
1.9
2.0
U.
S
.A.
On
ly
750
2.9
3.0
3.1
3.1
775
2.7
2.8
2.9
3.0
4001
800
2.6
2.7
2.8
2.8
(1220)
825
2.4
2.5
2.6
2.7
850
2.3
2.4
2.4
2.5
to
875
2.1
2.2
2.3
2.4
900
2.0
2.1
2.2
2.2
5000
925
1.9
2.0
2.0
2.1
(1524)
950
1.8
1.9
1.9
2.0
975
1.8
1.8
1.8
1.9
1000
1.8
1.8
1.8
1.8
U.
S
.A
.
On
ly
725
2.9
3.0
3.1
3.1
750
2.7
2.8
2.9
3.0
5001
775
2.5
2.6
2.7
2.8
(1524)
800
2.4
2.4
2.5
2.6
825
2.2
2.3
2.4
2.5
to
850
2.1
2.2
2.2
2.3
875
2.0
2.0
2.1
2.2
5400
900
1.9
1.9
2.0
2.1
(1646)
925
1.8
1.8
1.9
1.9
950
1.8
1.8
1.8
1.8
975
1.8
1.8
1.8
1.8
1000
1.8
1.8
1.8
1.8