—13—
PERFORMANCE DATA (CONT)–STANDARD ECM INDOOR MOTOR
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE
-
10–20
HEATING EXTENDED PERFORMANCE TABLE
30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.
604B036 COOLING PERFORMANCE TABLE
Temp (F)
Outdoor Air
Entering
Condenser
Evaporator Air—CFM/BF
1100/0.06
1225/0.07
1400/0.08
Evaporator Air — Ewb (F)
62
63*
67
72
62
63*
67
72
62
63*
67
72
75
TC
36.2
36.8
39.7
43.8
36.9
37.4
40.3
44.4
37.9
38.1
41.0
45.1
SHC
33.2
26.7
27.8
22.3
34.7
27.9
29.0
23.1
36.9
29.6
30.9
24.2
kW
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.9
85
TC
34.6
35.1
37.9
41.8
35.3
35.6
38.4
42.4
36.4
36.3
39.1
43.1
SHC
32.4
26.0
27.1
21.6
34.0
27.1
28.3
22.4
35.6
28.9
30.2
23.6
kW
2.9
2.9
3.0
3.0
3.0
3.0
3.0
3.0
3.1
3.1
3.1
3.2
95
TC
33.0
33.4
36.0
39.7
33.7
33.8
36.5
40.2
34.8
34.4
37.0
40.8
SHC
31.6
25.3
26.4
20.9
32.9
26.4
27.6
21.7
34.4
28.1
29.4
22.8
kW
3.2
3.2
3.3
3.3
3.3
3.3
3.3
3.4
3.4
3.4
3.4
3.5
105
TC
31.3
31.5
34.0
37.5
32.1
31.9
34.3
37.9
33.1
32.4
34.9
38.4
SHC
30.6
24.5
25.6
20.1
31.5
25.7
26.8
20.9
32.8
27.3
28.6
22.0
kW
3.6
3.6
3.6
3.6
3.6
3.6
3.7
3.7
3.8
3.7
3.8
3.8
115
TC
29.6
29.4
31.8
35.0
30.4
29.8
32.1
35.4
31.3
30.3
32.6
35.8
SHC
29.3
23.7
24.8
19.3
30.0
24.8
26.0
20.0
31.0
26.4
27.7
21.1
kW
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.1
4.1
4.1
4.2
125
TC
27.8
27.2
29.4
32.4
28.4
27.5
29.7
32.7
29.3
28.0
30.1
33.0
SHC
27.5
22.8
23.9
18.4
28.2
23.8
25.0
19.1
29.0
25.4
26.7
20.2
kW
4.4
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.5
4.5
4.5
4.5
604B036
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
-10
0
10
17
20
60
1100
TC
12.1
11.2
15.1
13.9
18.5
16.9
21.4
19.5
22.8
20.7
kW
2.25
2.34
2.43
2.49
2.51
1225
TC
12.3
11.4
15.4
14.2
18.7
17.2
21.7
19.7
22.9
20.7
kW
2.28
2.37
2.44
2.50
2.53
1400
TC
12.8
11.8
15.8
14.6
19.3
17.7
22.0
20.1
23.2
21.0
kW
2.37
2.44
2.53
2.56
2.59
70
1100
TC
11.1
10.3
14.3
13.1
17.6
16.1
20.6
18.8
21.9
19.9
kW
2.43
2.55
2.65
2.74
2.77
1225
TC
11.4
10.5
14.5
13.4
17.9
16.4
20.6
18.8
22.4
20.3
kW
2.47
2.58
2.67
2.76
2.78
1400
TC
11.8
10.9
15.0
13.8
18.4
16.9
21.2
19.3
23.0
20.8
kW
2.51
2.65
2.73
2.82
2.82
80
1100
TC
10.0
9.2
13.2
12.2
16.7
15.3
19.3
17.6
20.8
18.8
kW
2.61
2.75
2.89
2.97
3.01
1225
TC
10.2
9.5
13.5
12.5
17.0
15.6
19.6
17.9
21.2
19.2
kW
2.65
2.79
2.91
2.99
3.03
1400
TC
10.7
9.9
14.1
13.0
17.5
16.1
20.1
18.4
21.7
19.7
kW
2.73
2.87
2.97
3.05
3.08
604B036
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
30
40
47
50
60
60
1100
TC
27.3
23.9
32.6
32.6
36.6
36.6
37.8
37.8
42.1
42.1
kW
2.59
2.68
2.74
2.77
2.86
1225
TC
27.6
24.2
32.8
32.8
36.8
36.8
37.9
37.9
42.2
42.2
kW
2.60
2.67
2.72
2.75
2.83
1400
TC
28.0
24.5
33.0
33.0
37.0
37.0
38.2
38.2
42.2
42.2
kW
2.65
2.71
2.75
2.77
2.84
70
1100
TC
26.9
23.6
32.1
32.1
36.0
36.0
37.1
37.1
41.2
41.2
kW
2.84
2.94
3.01
3.04
3.14
1225
TC
27.1
23.7
32.3
32.3
36.2
36.2
37.3
37.3
41.4
41.4
kW
2.85
2.94
3.00
3.03
3.12
1400
TC
27.5
24.1
32.5
32.5
36.4
36.4
37.5
37.5
41.6
41.6
kW
2.90
2.97
3.02
3.04
3.11
80
1100
TC
26.7
23.4
31.6
31.6
35.5
35.5
36.5
36.5
40.4
40.4
kW
3.13
3.23
3.30
3.33
3.44
1225
TC
26.9
23.5
31.8
31.8
35.6
35.6
36.7
36.7
40.6
40.6
kW
3.13
3.23
3.29
3.32
3.42
1400
TC
27.2
23.9
32.3
32.3
35.9
35.9
37.0
37.0
40.8
40.8
kW
3.17
3.25
3.30
3.33
3.40
Содержание 604B
Страница 24: ...24 TYPICAL WIRING SCHEMATIC 230 1 60 SHOWN...
Страница 25: ...25 TYPICAL WIRING SCHEMATIC 208 230 3 60 SHOWN 1 3 2...