1. The Red LED to the right of P-1 will illuminate whenever the limit switch is open.
2. The Green LED below the left end of P-1 will flash when the blower motor is operating.
The LED will flash one time for each 100 RPM.
3. The Green LEDs above Y1, Y/Y2, G, O, and W will illuminate whenever there is a 24V
input from the thermostat.
4. The Green LED above DH will illuminate whenever there is not a 24VAC input applied.
P1
A04194
Fig. 19 -- Control Board