![BRP Evinrude Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/brp/evinrude/evinrude_installation-manual_2820608084.webp)
82
FUEL AND OIL PRIMING
OIL SUPPLY PRIMING
15 – 90 HP Models
Use
Evinrude Diagnostics
software to make sure
the
EMM
is programmed for the type of oil being
used.
Start the outboard. Use the oil priming function in
the software to make sure the system is com-
pletely primed.
Use the
Prime Oil System
button of the
Dynamic
Test
screen to prime the oil pump.
If the “LOW OIL” warning was previously tested
(see
LOW OIL Warning Test
on p. 77), the warn-
ing should turn OFF during oil system priming.
Observe oil flow through all oil distribution hoses.
Air must be purged during the priming procedure.
Small bubbles are acceptable. Large bubbles
must be eliminated through continued priming.
Repair any fuel or oil leaks.
The oiling system on these models can also be
primed using the Self-Winterizing feature if diag-
nostics software is not available. Refer to
Opera-
tor’s Guide
.
Dynamic Test
Screen
1.
Prime Oil System button
008570A
40 – 90 HP Models
1.
Oil distribution hoses
007997
1
1
15 – 30 HP Models
1.
Oil distribution hoses
007130
1.
Oil distribution hose
2.
Small bubbles
3.
Large bubbles
004398
1
1
1
3
2
Содержание Evinrude