![BRP Evinrude Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/brp/evinrude/evinrude_installation-manual_2820608062.webp)
60
OUTBOARD RIGGING
EVINRUDE E-TEC 60° V MODELS 115–200 HP
Make sure that idle stop of the throttle lever is
against the crankcase.
Adjust the throttle cable trunnion to align with the
trunnion block. Place the cable trunnion in the
trunnion block.
IMPORTANT:
Move control handle to FOR-
WARD and pull back slowly to NEUTRAL. Make
sure the engine throttle lever is against the stop. If
not, remove slack by adjusting cable trunnion.
Install trunnion cover and screw. Tighten screw to
a torque of 60 to 80 in. lbs. (7 to 9 N·m).
Battery Cable Connections
Install battery cables on starter solenoid and main
ground stud.
SystemCheck
Harness
Connections
Remove flywheel/harness connector cover.
Before installing electrical connectors, check that
the seal is in place. Clean off any dirt from con-
nectors. Apply a light coat of
Electrical Grease
to
the seal only. DO NOT fill connectors with
Electri-
cal Grease
.
1.
Throttle lever stop
004947
1.
Trunnion cover and screw, throttle cable
004958
1
1
1.
Positive (+) battery connection
2.
Ground (–) connection
004953
004954
1.
Seal
42079A
2
1
1
Содержание Evinrude
Страница 1: ......
Страница 2: ......
Страница 32: ...30 BOAT RIGGING NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 52: ...50 OUTBOARD INSTALLATION NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 76: ...74 OUTBOARD RIGGING NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 100: ......