4 - 9
Adjustment
Adjustment
Needle bar rising
1. Attach the front cover assy..
2. Remove the presser foot, the needle plate B and the needle plate A, and then remove the inner rotary hook.
3. Start the test mode.
4. Select the pattern number "02" (3-point needle drop mode).
5. Move the needle to the left with the
(Reverse stitch button), and then turn the power off.
6. Turn the pulley by hand and move the needle to its lowest position.
7. Remove the base cover.
8. Loosen the 2 socket set screws (CP, M5 x 5) on the lower shaft pulley D.
9. Turn the outer rotary hook by hand and adjust the right edge of the needle aligns with the outer rotary hook point
when raising up the needle bar 3.1 to 3.3mm from its lowest position.
10. Tighten the 2 socket set screws (CP, M5 x 5) on the lower shaft pulley D.
11. Attach the base cover.
Socket set screws
(CP, M5 x 5) (2pcs.)
Lower shaft pulley D
3.1 - 3.3mm
Base cover
The right edge of the needle aligns with the
outer rotary hook point when raising up the
needle bar 3.1 to 3.3mm from its lowest position.
Содержание HS-3000
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 9: ...vi ...
Страница 16: ...2 1 2 Disassembly Main parts 2 2 Feed unit 2 22 Needle presser unit 2 30 ...
Страница 17: ...2 2 Main parts Main parts location diagram Main unit ...
Страница 37: ...2 22 Feed unit location diagram Main unit ...
Страница 45: ...2 30 Needle presser unit location diagram Main unit ...
Страница 55: ...3 2 Main parts Main parts location diagram Main unit ...
Страница 77: ...3 24 Main unit Main parts 36 Accessory table attachment 1 Attach the accessory table 1 1 ...
Страница 78: ...3 25 Assembly Feed unit Feed unit location diagram Main unit ...
Страница 90: ...3 37 Assembly Needle presser unit Needle presser unit location diagram Main unit ...
Страница 163: ...7 12 ...
Страница 164: ......