4 - 6
Adjustment
Left base line needle drop
1. Attach the front cover assy..
2. Start the test mode.
3. Select the pattern number "02" (3-point needle drop mode).
4. Move the needle to the left with the
(Reverse stitch button), and then turn the power off.
5. Turn the pulley by hand, until the needle top comes to the needle plate surface.
6. Loosen the socket screw (M3 x 10).
7. Turn the zigzag adjusting nut and adjust the needle top drops in the right side of “V” groove on the needle plate A.
8. Tighten the socket screw (M3 x 10).
*Key point
• Refer to the next page “4-7 Rotary hook unit position“ when it cannot be adjusted correctly using the above
procedure.
Needle top
drops in
shadow area.
"V" groove
Socket
screw (M3 x 10)
Zigzag adjusting nut