1-36
Confidential
5.
SOFTWARE SETTING PROBLEMS
The machine may not print the data correctly if there are incorrect software settings.
User Check
• Check that the USB cable and the network cable is not damaged or broken.
• Check that the correct machine is selected if you have an interface switching device.
• Check the descriptions on the software setting in the user’s guide.
• Try resetting the factory settings.
Step
Cause
Check
Result
Remedy
1
Failure inside the
machine
Does the machine print
“Printer Settings” ?
(Refer to
in Chapter 5.)
No
Identify the error type, and
then refer to the specified
section of this chapter.
2
Machine
connection
For Macintosh, has the
product ID been
verified?
No
Verify the product
ID.Product ID:
HL-2140: 0033*
HL-2150N: 0034*
HL-2170W: 0035*
* Hexadecimal
3
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
Содержание HL-2150N
Страница 56: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 97: ...3 41 Confidential 8 19 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 35 Filter ASSY ...
Страница 127: ...3 71 Confidential 8 30 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 66 Rubber foot ...
Страница 142: ...4 10 Confidential Serial label Drive sub ASSY Drive sub ASSY Serial label Serial label Laser unit 2 to 10mm ...
Страница 167: ...6 5 Confidential High voltage Power Supply PCB Circuit Diagram ...
Страница 168: ...6 6 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 169: ...6 7 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 170: ...6 8 Confidential Wiring Diagram ...