Step
Cause
Check
Result
Remedy
1
Corona wire
failure
Are the electrodes on
the drum unit and
machine body dirty?
Yes
Clean both electrodes.
(Refer to
)
2
Is the corona wire
damaged?
Yes
Replace the drum unit.
3
Scanner harness
of the laser unit
connection
failure
Is the scanner harness
of the laser unit
connected securely?
No
Reconnect the scanner
harness of the laser unit.
4
FG harness
ASSY connection
failure
Is the FG harness ASSY
between the laser unit
and main PCB ASSY
connected securely?
No
Reconnect the FG harness
ASSY between the laser
unit and main PCB ASSY
securely.
5
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
6
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
7
Laser unit failure
Is the problem solved
after replacing the laser
unit?
Yes
Replace the laser unit.
Содержание HL-2150N
Страница 56: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 97: ...3 41 Confidential 8 19 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 35 Filter ASSY ...
Страница 127: ...3 71 Confidential 8 30 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 66 Rubber foot ...
Страница 142: ...4 10 Confidential Serial label Drive sub ASSY Drive sub ASSY Serial label Serial label Laser unit 2 to 10mm ...
Страница 167: ...6 5 Confidential High voltage Power Supply PCB Circuit Diagram ...
Страница 168: ...6 6 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 169: ...6 7 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 170: ...6 8 Confidential Wiring Diagram ...