Confidential
App. 1-39
< WSW34 >
Selector No.
Function
Setting and Specifications
1
|
3
Erasing time length of ICM tone
recorded preceding the tone
detection starting point in the
case of automatic line
disconnection due to no voice
signal received
No. 1 2 3
0 0 0: 0 sec.
0 0 1: 1 sec.
0 1 0: 2 sec.
0 1 1: 3 sec.
1 0 0: 4 sec.
1 0 1: 5 sec.
1 1 0: 6 sec.
1 1 1: 7 sec.
4
5
No. of CNG cycles to be
detected
(when the line is connected via
the external telephone in the
external TAD mode or via the
machine in F/T mode)
No. 4 5
0 0:
0.5
0 1:
1
1 0:
1.5
1 1:
2
(A)
(B)
(C)
(D)
6
7
Number of DTMF tone signals
for inhibiting the detection of
CNG during external TAD
operation
No. 6 7
0 0:
3
0 1:
2
1 0:
1
1 1:
OFF
8 Not
used.
Note:
Selectors 1 through 5 are applicable to models equipped with built-in TADs.
- Selectors 1 through 3: Erasing time length of ICM tone recorded preceding the tone
detection starting point in the case of automatic line
disconnection due to no voice signal received
If the machine has disconnected the line after detection of disconnection tone in ICM
recording, it erases tone recorded preceding the tone detection starting point for the time
length set by these selectors.
- Selectors 4 and 5: No. of CNG cycles to be detected (when the line is connected via the
external telephone in the external TAD mode or via the machine in
F/T mode)
The machine interprets a CNG as an effective signal if it detects a CNG signal by the
number of cycles specified by these selectors when the line is connected via the external
telephone in the external TAD mode or via the machine in F/T mode.
- Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG
during external TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to “1, 1,” the CNG detection will not be inhibited.
Содержание DCP-9045CDN
Страница 151: ...Confidential 3 18 PF DRIVE Development view 37 38 39 40 41 42 43 44 45 46 47 48 Frame unit Front ...
Страница 239: ...Confidential 3 106 11 Remove the LCD from the Backlight module Fig 3 129 LCD Backlight module ...
Страница 349: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Страница 365: ...Confidential 5 5 Black and white level data for scanning compensation Fig 5 1 ...
Страница 382: ...Confidential 5 22 Cover page sample Fig 5 12 End page sample Fig 5 13 ...
Страница 404: ...Confidential 6 1 CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM Charge High voltage Power Supply PCB Circuit Diagram 1 4 ...
Страница 405: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Страница 406: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Страница 407: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Страница 408: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Страница 409: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Страница 410: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 411: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 413: ...Confidential 6 10 Filter PCB Circuit Diagram ...