![Brother DCP-9045CDN Скачать руководство пользователя страница 423](http://html.mh-extra.com/html/brother/dcp-9045cdn/dcp-9045cdn_service-manual_53339423.webp)
Confidential
App. 1-8
< WSW04 >
Selector No.
Function
Setting and Specifications
1
Earth function in transfer facility
(Not used.)
0: Provided
1: Not provided
2
3
Dual tone detection frequency
in ICM recording
No. 2 3
0 0: 350 and 440 Hz
0 1: 440 and 480 Hz
1 0: 480 and 620 Hz
1 1: 480 and 620 Hz
(A)
(B)
(C)
(C)
4
Dual tone detection sensitivity
in ICM recording
0: Normal
1: High
5
Length of time added to time
designated by selectors 3 and 4
on the WSW 24 (time between
CML ON and pseudo ring
backtone return).
0: Not added
1: +4 seconds added
6
|
8
Break time length for flash
function
No. 6 7 8
0 0 0: 80 ms
0 0 1: 100 ms
0 1 0: 110 ms
0 1 1: 120 ms
1 0 0: 200 ms
1 0 1: 250 ms
1 1 0: 500 ms
1 1 1: 700 ms
Note:
- Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.
- Selectors 2 through 4 are applicable to models equipped with built-in TADs.
- Selector 1: Earth function in transfer facility (Not used.)
This selector determines whether or not the earth function is added to the transfer setting
menu to be accessed by the function switch.
- Selectors 2 and 3: Dual tone detection frequency in ICM recording
If the machine detects either of the frequencies set by these selectors in ICM recording, it
disconnects the line. For example, if these selectors are set to “0, 0” the machine
disconnects the line upon detection of 350 Hz or 440 Hz.
- Selector 4: Dual tone detection sensitivity in ICM recording
Setting this selector to “1” increases the tone detection sensitivity in ICM recording.
- Selectors 6 and 8: Break time length for flash function
These selectors set the break time length. This setting is effective only when the flash
function is selected for the
Search/Speed Dial
button by using the function switch.
Содержание DCP-9045CDN
Страница 151: ...Confidential 3 18 PF DRIVE Development view 37 38 39 40 41 42 43 44 45 46 47 48 Frame unit Front ...
Страница 239: ...Confidential 3 106 11 Remove the LCD from the Backlight module Fig 3 129 LCD Backlight module ...
Страница 349: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Страница 365: ...Confidential 5 5 Black and white level data for scanning compensation Fig 5 1 ...
Страница 382: ...Confidential 5 22 Cover page sample Fig 5 12 End page sample Fig 5 13 ...
Страница 404: ...Confidential 6 1 CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM Charge High voltage Power Supply PCB Circuit Diagram 1 4 ...
Страница 405: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Страница 406: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Страница 407: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Страница 408: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Страница 409: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Страница 410: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 411: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 413: ...Confidential 6 10 Filter PCB Circuit Diagram ...