11. TABLE OF ERROR CODES
BAS-300G-484, BAS-300G-484 SF
71
Data editing-related errors
Code
Cause and remedy
E500
The enlargement ratio setting caused the sewing data to extend outside the sewing area.
Set the enlargement ratio again.
E501
Sewing data that exceeds the sewing machine's sewing area was loaded.
Check the size of the sewing data.
E502
The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm.
Set the enlargement ratio again.
E510
Invalid code in sewing data.
Reload the data from the CF card or floppy disk.
E511
No end code has been input into sewing data.
Input an end code, or change the program number.
E512
Number of stitches exceeds allowed maximum.
E520
Extended option output number already exists. Change the extended option output number.
If not using the extended option output, initialize the data to clear the extended option output data.
E530
Changing program number is prohibited.
Device-related errors
Code
Cause and remedy
E670
Turn off the power, and then contact the place of purchase.
E671
Turn off the power, and then contact the place of purchase.
Содержание BAS-300G-484