6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
BAS-300G-484, BAS-300G-484 SF
34
6-3. List of memory switch settings
No.
Setting
range
Setting items
Initial value
Work clamp lift timing after sewing is completed
OFF
Lifts at the final stitch position.
001
ON
Lifts after moving to the sewing start position.
ON
Separate-type work clamp drop operation (pneumatic work clamp specifications)
0
Left and right work clamp drop at the same time.
1
Work clamp drops in the order left
→
right.
002
2
Work clamp drops in the order right
→
left.
0
Sewing start speed
OFF
The sewing speed for the first 1
−
5 stitches is set by memory switch numbers 151
−
155.
(Refer to the service manual for details of memory switch Nos. 151
−
155.)
100
ON
1st stitch at 400 sti/min, 2nd stitch at 400 sti/min, 3rd stitch at 600 sti/min, 4th
stitch at 900 sti/min, 5th stitch at 1,300 sti/min
OFF
Single-stitch test feed
OFF
Test feed starts when the foot switch (start switch) is depressed, and it continues
automatically until the final stitch.
200
ON
Test feed is carried out one stitch at a time when the foot switch (start switch) is
depressed (feed becomes continuous if the foot switch [start switch] is
continuously depressed).
In addition, when the TEST indicator is illuminated, test feeding will move forward
one stitch at a time when the machine pulley is turned by hand.
OFF
Production counter display
OFF
Lower thread counter display
300
ON
Production counter display
OFF
User programs
OFF Disabled
400
ON
User program mode is enabled.
OFF
Cycle programs
OFF Disabled
401
ON
When sewing user programs, the set programs are sewn in numeric order.
OFF
Maximum reduction ratio (mm display) (*)
OFF
Displayed as %.
402
ON
Displayed as mm.
OFF
Split mode selection
0
Continuous split (split menu is disabled before split detection)
1
Continuous split (split menu is always enabled)
403
2 Independent
split
0
* The mm display may differ slightly from the actual sewing size.
Содержание BAS-300G-484