11. TABLE OF ERROR CODES
BAS-300G-484, BAS-300G-484 SF
68
11. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before
opening the control box cover. Touching areas where high voltages are present will result in serious injury from electric
shocks.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window.
Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Cause and remedy
E010
Stop switch was pressed. Press the RESET key to clear the error.
E011
Stop switch was pressed. Press the RESET key to clear the error.
Press the key to move the feed mechanism so that you can continue sewing.
E015
The stop switch was still being pressed, or there is a problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E016
Problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E025
The power was turned on while the start switch was still being depressed, or the start switch was depressed without
the work clamp being lowered.
If the power has been turned on while the start switch was still depressed, turn off the power and check the start
switch.
If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the work
clamp.
E035
The work clamp switch is depressed.
Turn off the power, and then check the work clamp switch.
E036
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly.
Use a foot switch that matches specifications, or initialize the memory switch settings.
E050
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E051
Machine head tilting was detected while the sewing machine was operating.
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
E055
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E065
An operation panel key was still being pressed when the power was turned on, or key is faulty.
Turn off the power and check the operation panel.