20
3.1 E
VERY
T
HREE
M
ONTHS
(
CONT
’
D
)
5.
Clean the
condensation tray
with a damp
cloth.
6.
Check the exterior
air intake hood
:
• Make sure there are no leaves, twigs, ice or snow that could be drawn into the vent.
• Clean if necessary.
7.
Reassemble the components:
• Filters
• Door (The door is secured when you hear a click.)
8.
Reconnect the power supply.
VD0101
CAUTION
Even a partial blocking of this air vent could cause the unit to malfunction.
3.2 A
NNUAL MAINTENANCE
(
FALL
)
Repeat steps 1 to 6 from the previous Section and continue with the following steps:
1.
Clean the recovery core
A-
Polypropylene core (heat recovery unit)
•
Remove the recovery core.
•
Let it soak in a mixture of cold or lukewarm
water and mild soap (dishwashing liquid).
•
Rinse thoroughly.
•
Shake the core to remove excess water
and let it dry.
B-
Enthalpic paper core (heat and humidity recovery
unit).
•
Remove the recovery core.
•
Remove dust using a vacuum cleaner with a soft brush attachment.
VD0102
CAUTION
Handle the recovery core with care.
CAUTION
This type of recovery module cannot be washed with water.
WARNING
Dangerous voltage may be present. During maintenance and repairs, the
unit must always be turned off, then unplugged. We take great care to
minimize sharp edges; however, please proceed with caution when handling
all components. When cleaning the unit, it is recommended to wear safety
glasses and gloves.
0
!