17

2.5 U

SING THE

VT2W M

AIN

C

ONTROL

(

CONT

D

)

U

NDERSTANDING

 

THE

 

LIGHT

 

INDICATORS

AIR SUPPLY CONTROL

CONDENSATION CONTROL

MAXIMUM SPEED

AIR EXCHANGE IN PROGRESS

MIN.

MAX.

CONTINUOUS

INTERMITTENT

20 MIN

.

ON

40 MIN.

OFF

VC002

8

LIGHTS UP

when the intermittent

mode has been selected.

FLASHES

when maintenance is

required (see Section 3).

LIGHTS UP

when the 
system is
o p e r a t i n g
( ex h a u s t i n g
stale air from
the house
and drawing
in fresh air).

LIGHTS UP

when the

control has detected
excess humidity. This
forces the motor to
operate at high speed.
The light indicator
turns off when the
humidity drops to the
level associated with
the temperature
selected on knob 

B

.

2.6 U

SING THE

D

EHUMIDISTAT

M

AIN

C

ONTROL

Location:

Located in the busiest area of the
house.

Purpose:

To reduce condensation on windows.

During fall, winter and spring:

Adjust knob 

A

to the desired maximum humidity

level.
NOTE: Do not select a level below 30%. This 

could lead to excessive dryness in the 
air causing discomfort for the occupants.

During summer: 

Adjust knob 

A

to the “OFF’’ position or to the

highest humidity setting if there is no “OFF’’
position on your control.

Location:

Located on the side of the unit, only on models HRV100H and HRV200H.

Purpose:

To adjust air supply.

How to operate the unit on a daily basis: 

Select “LOW’’ or “HIGH’’ speed:

• Select “LOW SPEED’’ for normal daily operation.

• Select “HIGH SPEED’’ for excess pollutants and

humidity (parties, odors, smoke, etc.) 

How to turn the unit off: 

Select the “REMOTE’’ position.

NOTE: If the HRV100H or the HRV200H is connected to VT1W main control, 

the 3-position switch must be in “REMOTE’’ position.

COM

FOR T ZO

N E

O

FF

%

REL

ATIVE HUMIDI

TY

70%

60%

50%

40%

30%

25%

20%

HUMIDITY

CONTROL

DURING FALL, WINTER 
AND 

S

PRING, 

S

ET THE 

DIAL ACCORDING TO 

THE DE

S

IRED MAXIMUM 

INDOOR HUMIDITY LEVEL. 

DURING 

S

UMMER 

S

ET 

THE DIAL TO THE 

OFF PO

S

ITION. 

VC0071

A

Appearance may vary.

VENTILATION

REMOTE

ARRÊT

LOW 

S

PEED

BA

SS

E VITE

SS

E

HIGH 

S

PEED

HAUTE VITE

SS

E

VC0072

WARNING

Optional controls or the Dehumidistat can still activate the unit, even when
it is in the “REMOTE’’ position. Unplug the unit to be absolutely sure it is off.

0

!

2.7 U

SING THE

3-P

OSITION

S

WITCH

Содержание HRV100H

Страница 1: ...RV100H HRV200H ERV100HC ERV200HC These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA They meet ENERGY STAR requirements...

Страница 2: ...air throughout your home for years to come 2 ABOUT THIS MANUAL PRODUCT CAUTION Some activities create dust or vapors which may damage your unit You must therefore turn off and unplug your unit in the...

Страница 3: ...your Control Devices 7 8 2 2 Using the Platinum Main Control 9 11 2 3 Using the Deco Touch Main Control 12 14 2 4 Using the VT1W Main Control 15 2 5 Using the VT2W Main Control 16 17 2 6 Using the De...

Страница 4: ...r from your home By eliminating accumulated pollutants and humidity it maintains an optimum air quality and an ideal relative humidity 1 2 PURPOSE OF THE VENTILATION SYSTEM VH0025 NOTES 1 Shown with a...

Страница 5: ...rgy to warm the fresh air being supplied This heat recovery process is accomplished in such a way that the stale air is never mixed with the fresh air Example in winter OUTSIDE INSIDE STALE AIR TO OUT...

Страница 6: ...le the unit shifts to maximum speed and the dampers close After defrosting the unit returns to the operating mode selected by the user 1 4 DEFROSTING 1 5 SPECIFICATIONS Model 1001 ERV 1001 HRV HRV100H...

Страница 7: ...Deco Touch Pages 12 14 VT2W Pages 16 17 2 HOW TO OPERATE THE UNIT USING CONTROLS VC0104 SMART SET MODE PREF CONDENSATION CONTROL AIR SUPPLY CONTROL MIN MAX OFF AIR EXCHANGE 20 C 4 F 5 C 23 F 5 C 41 F...

Страница 8: ...10 Turn Past VC0017 20 30 40 50 60 MINUTES HOLD MAIN CONTROLS CONT D 3 Position Switch Page 17 VENTILATION REMOTE ARR T LOW SPEED BASSE VITESSE HIGH SPEED HAUTE VITESSE VC0072 Dehumidistat Page 17 COM...

Страница 9: ...eds and programming options 6 9 8 10 11 12 13 ON SCREEN INDICATORS CASING INDICATORS AND KEYS SMART SET MODE PREF VC0100 C B A G E F D A SMART key Enables and disables the SMART mode B Set key Press 3...

Страница 10: ...etting SETTING AVAILABLE VALUE DEFAULT OPTIONS CURRENT DAY MON TUE WED THU FRI SAT SUN MON HOUR DISPLAY 12 00 AM OR 24 00 12 00 AM CURRENT HOUR FROM 0 TO 12 OR 24 12 CURRENT MINUTE FROM 00 TO 59 00 TE...

Страница 11: ...on screen Use to select the ventilation speed or type Press SET key B to confirm and go to daily Period 2 Period 2 will appear on screen and hour display will flash Proceed as for Period 1 for all da...

Страница 12: ...ing mode label will then scroll up or down on LCD screen 20 MIN H The ventilation unit exchanges air intermittently on a one hour cycle as follows OFF for 40 min or recirculation on high speed for 40...

Страница 13: ...55 Still flashing Press OK button to accept the new value and go to next settting Two lines are flashing to show that OFF is in stand by default configuration setting OR Recirculation arrows are turni...

Страница 14: ...idity appears if it was not shown see example beside Once the target humidity level is reached the unit goes back into its original operating mode and AUTO disappears from LCD screen NOTE If the actua...

Страница 15: ...rol for a few months Set knob B at the SUMMER position during this period Setting during the fall winter and spring months 1 Determine the humidity level in your house bring the knob B counterclockwis...

Страница 16: ...an optional control is active ADJUSTING CONDENSATION CONTROL Setting during the summer months Normally there is no condensation on your windows during this period which therefore eliminates the need...

Страница 17: ...using discomfort for the occupants During summer Adjust knob A to the OFF position or to the highest humidity setting if there is no OFF position on your control Location Located on the side of the un...

Страница 18: ...minutes twice for 40 minutes or three times for a 60 minute activation Results expected 1 Motor speed High for 20 40 or 60 minutes 2 Indicator light goes ON and flashes every 5 seconds one time to ind...

Страница 19: ...ters to remove excess water and let dry NOTE Washing the filters in the top tray of the dishwasher is possible but the aluminum frame might tarnish 3 1 EVERY THREE MONTHS Regular maintenance should be...

Страница 20: ...ene core heat recovery unit Remove the recovery core Let it soak in a mixture of cold or lukewarm water and mild soap dishwashing liquid Rinse thoroughly Shake the core to remove excess water and let...

Страница 21: ...rs Door 4 Reconnect the power supply VD0106 C Remove the blower assembly D Check for any dust accumulation on the blades E Clean with a small brush if necessary VD0104 VD0105 CAUTION Do not oil the mo...

Страница 22: ...on 2 Operate the unit at maximum speed MAX during activities generating excess humidity family gatherings extra cooking etc Leave curtains half open to allow air circulation Store all firewood in a cl...

Отзывы: