38
TROUBLE SHOOTING
GUIDE
1. FILTER BLEEDS TASTE
AND ODOR OR SEDIMENT
A. Bypass valve is open
B. Electrical service to unit has
been interrupted
C. Defective or stripped media bed
D. Quality of water has worsened
E. Filter capacity too small
F. Filter not backwashing enough
G. Excessive water usage - calen-
dar clock models
A. Close bypass valve
B. Assure permanent electrical service (check fuse, plug or
switch)
C. Replace media
D. Have water sample analyzed to determine any change
E. Replace with larger unit or add another filter
F. Be sure flow control is not clogged or drain line restricted.
Be sure water pressure has not dropped and that pump has
sufficient capacity
G. Increase frequency of regeneration. Make sure there are no
leaks in toilets or sinks
2. FILTER FAILS TO
REGENERATE
A. Electrical service to unit has
been interrupted
B. Timer is defective
C. Power failure
D. Timer motor does not run
A. Assure permanent electrical service (check fuse, plug or
switch)
B. Replace timer
C. Reset time of day
D. Replace defective motor
3. FILTER REGENERATES
EVERY DAY
A. Faulty gear train
A. Check the mechanical linkage on the timer control to elimi-
nate possible binding in the gear train
4. LOSS OF WATER
PRESSURE
A. Iron or turbidity build-up in filter
B. Filter not regenerating often
enough
C. Not enough water volume or
pressure to backwash properly
A. Clean control and treat bed with Iron Out. Increase frequency
of regeneration
B. Increase frequency of regeneration
C. Correct water supply problem
5. LOSS OF MEDIA THROUGH
DRAIN LINE
A. Air in water system
B. Backwash rate too fast
A. Assure that well system has proper air eliminator control.
Check for dry well condition
B. Check drain flow control for proper flow rates
6. DRAIN FLOWS
CONTINUOUSLY
A. Foreign material in control
B. Timer motor stopped or jammed
A. Remove piston assembly and inspect bore. Remove foreign
material and check control in various regeneration positions
B. Replace timer motor
PROBLEM
CAUSE
CORRECTION