29
REPLACE TIMER
4 X Screws
1.
Disconnect the meter cable from the
meter. (If flow meter is attached)
2.
Remove four screws from the back of
the valve cover
3.
Remove the front cover of the valve.
4.
Remove the piston screw and
washer from the piston rod.
5.
Remove the two screws from the powerhead as shown
6.
Life the powerhead from the valve body assembly
7.
Replace the powerhead by reverse following the steps in this section
Piston Screw
2 X Screws from Powerhead
Washer
Powerhead
Assembly
Valve Body
Assembly
REPLACE MOTOR
1.
Remove Screws from the back of the valve
and pull the cover
2.
Remove all connections from the
circuit board
3.
Remove the two screws from the motor.
Remove the motor and watch for the pin
under the motor.
4.
Replace the motor, connections and cover
Meter Cable
Front Cover
1.
3.
2.
4.
Cover 4X Screws
2X Screws
Motor
Front Cover
Содержание BPF89CATCB100TOC
Страница 39: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...