19
No
Description
Cause
Solution
1
Start the machine but
not display or the main
switch indicating lamp
not light
1. Socket fault
2.power board fault
3.The cable between the
power board & main board
come off
4.computer board fault
1. Check the power supply circuit,
plug and socket
2. Change the power board
3. Connect the main board cable
and reconnect and fix
4. Change the computer board
and recalibrate
2
Display is normal but
the start button and
input push button not
working.
1.contact switch not good
2.machine breakdown
1. Check the control panel cable.
2 Switch on the machine again.
3
display[0]-[0]
without
the other value display
1.sensor cable come off
2.computer board program
fault
1. Check the piezoelectricity
sensor cable.
2. Change the computer board
and recalibrate.
4
Not brake after start or
display ERR
–sp
photocell
sensor
troubleshooting
Check is the POS is active
through test. If it is active, check
the photocell sensor and change
if there is problem.
5
When start, the wheel
cannot spin
Check the program setup to
see if the hood monitor
In the program setup, set the [-P-]
to be [OFF]and without using of
the monitor or lower down the
machine hood.
6
The wheel clip the
weight for many times
bur cannot balance
the tire
The machine has not been
used for a long time or the
machine was bump.
So the weight self-calibration
according to the FIG 17 .
7
The unbalance display
of the wheel balancer
is not stable.
1. The machine affected by
the vibration when rotating.
2. The place of the machine
is not stable.
3. The wheel is not clamped
firmly.
4. The input of the data is not
correctly.
5. The machine is not
calibrated.
1. Repeat the operation
2. Avoid the vibration when
accessing the value.
3. Place the machine stable and
clamp the wheel properly.
4. Input the correct value.
5Make calibration.
8
After clamping the tire
which
has
be
balanced, the test data
will be larger.
1
、
The link between the
thread shaft and the main
shaft is not clean when
mount.
2
There is impurity on the
main shaft and or the flange.
1. Clean the link between the
thread shaft and the main shaft
and re-rotate and fix.
2Clean the impurity.
Содержание CB460 Series
Страница 1: ...I WHEEL BALANCER USER MANUAL Pls read this manual before operation ...
Страница 14: ...11 Press to the option select item Enter the self calibration see the following FIG 9 ...
Страница 26: ...23 ATACHMENT Ⅰ3 phase power board cable diagram brake resistant Power cable Motor cable transfor mer CPU cable ...
Страница 27: ...24 ATTACHMENT Ⅱ Single phase power board cable diagram ...
Страница 28: ...25 ATTACHMENT Ⅲ Electrical theory diagram Input ...