8
frequency stabilizer to keep the stable of the
voltage and frequency.
C
、
Requirement to the socket: Small size wheel
balancer should be equipped with the power cord
and the plug before out of the factory. The
customer should directly equip the socket
adapted to plug. But the use of the socket must
meet the following requirements
:
Ⅰ
rated capacity exceeds 500VA and the rated
current exceeds 15A
;
Ⅱ
Socket must have the reliable earth wire and
you cannot use the two pole socket without the
earth wire for the missing of the earth wire will
influence the accuracy and
interference-resistance of the wheel balancer.
Ⅲ
The best socket is one with the switch. The circuit
can break the circuit and cut off the power to
avoid the damage to the machine.
线路
Ⅴ
The best way is to have a special socket to
power the machine and not connect several
electrical device on one socket.
Pneumatic connect
A
、
Technical parameter of the lift
:
Work capacity
:
0.1~0.8MPa
(
0.5~0.8MPa for
normal operation
)
Accuracy
:
0.01MPa
Air source
:
This machine is not equipped with the
air supply which will be supplied by the customer.
The air pressure of the air source should be
controlled in the range of 0.6~0.9MPa. Then use
the pressure reduction valve on the lift to below
0.8MPa. The air supply must be equipped with
the filtration device and the accuracy of the
filtration should be 5μm. The medium
flow >0.15m3/min and the temperature should be
5~60
℃
. The lift is equipped with the quick
connect and the customer can insert the rubber
hose of Φ8 into the air source connect of the lift
and use the fastener to tight it. It is OK.
Environment
:
In accordance with the requirement
of the wheel balancer
NT
:
50Kg
size
:
1129×1190×728mm
(
L*W*H
)
B
、
Air pressure conversion
1Mpa=l0Bar
1Bar=14.5Psi
1Bar≈1Kg/cm2
Environment
:
In accordance with the requirement
of the wheel balancer
NT
:
50Kg
Size
:
1129×1190×728mm
(
L*W*H
)
B
、
Normal conversion of the air pressure
1Mpa=l0Bar
1Bar=14.5Psi
1Bar≈1Kg/cm2
C
、
Pneumatic theory diagram
Operation and operation caution
:
*Do not install the machine in the area too hot or
too cold and avoid placing the machine near the
heater, cock, air humidity device or the oven.
*Do not place the machine close to the window to
avoid the direct sunlight. If installed by the
window, you should equip the shield to cover the
machine such as curtain.
*Keep the machine from the chemicals such as
dust, ammonia, alcohol, thinner, power and
adhesive etc.
*Do not install the machine near the equipments
can produce the vibration and the air compressor.
*In the process of operation, except the operator,
any other person can not close the machine in
Содержание CB460 Series
Страница 1: ...I WHEEL BALANCER USER MANUAL Pls read this manual before operation ...
Страница 14: ...11 Press to the option select item Enter the self calibration see the following FIG 9 ...
Страница 26: ...23 ATACHMENT Ⅰ3 phase power board cable diagram brake resistant Power cable Motor cable transfor mer CPU cable ...
Страница 27: ...24 ATTACHMENT Ⅱ Single phase power board cable diagram ...
Страница 28: ...25 ATTACHMENT Ⅲ Electrical theory diagram Input ...