Installation Instructions
Outside wall installation example
Secure sidewall termination to fireplace
with Milpac
(DO NOT use silicone
) on
both inner exhaust and outer supply air
pipes. Once installed on the unit se-
cure the termination to the wall with
screws to each corner.
Horizontal termination
999
-
DV
-
HTCL
is to be used for direct connection to the unit. If extending the vent using
2
-
ply aluminum flex, a change to the
999
-
DV
-
HTC
is required.
The Brigantia 35
-
DVRS31NB(N)
-
2 requires 120v for the operating system. There is a factory installed electrical
box to accommodate the connections. (see wiring diagram pg. 20)
The fireplace comes complete with a battery back
-
up system that will operate the fireplace for a limited time
only in the event of a power outage.
The 120v circuit must be electrically grounded in accordance with the local codes or, in absence of local codes,
with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code CSA C22.1.
Electrical Considerations
Fig 12
-
A