35-DVRS31NB(N)-2
36
N O T E
When the fireplace is started in Smart Thermostat mode:
1.
The fan will automatically activate 5min after ignition and shut down 12min after fire is turned off.
2.
Manual Flame height adjustment is disabled.
REMOTE CONTROL SETUP AND OPERATION
ROOM THERMOSTAT (TRANSMITTER OPERATION)
The Remote Control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the
comfort level in a room.
•
To activate this function:
•
Press the Thermostat Key. The LCD display on the remote will change to show that the room thermostat is “ON” and
the set temperature is now active.
•
To adjust the temperature, press the Up/Down Arrow Keys until the desired temperature is displayed.
SMART THERMOSTAT (TRANSMITTER OPERATION)
The Smart Thermostat function adjusts the flame height automatically in accordance to the difference between the set point
and the actual room temperature. As the room temperature approaches the set point, the Smart Function will modulate the
flame down.
To activate this function:
•
Press the Thermostat Key until the word “SMART” appears to the right of the temperature bulb graphic.
•
To adjust the set temperature, press the Up/Down Arrow Keys until the desired set temperature is displayed.
Fig. 33
-
A
Fig. 33
-
B