![Brigantia 35-DVRS31NB-2 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/brigantia/35-dvrs31nb-2/35-dvrs31nb-2_users-installation-operation-and-maintenance-manual_2810513031.webp)
35-DVRS31NB(N)-2
31
LIGHTING INSTRUCTIONS
-
CAUTION
When operated for the first few times, the appliance will emit some odor and fumes. This is due to the
heat from the appliance evaporating the oils and solvents used in fabricating the appliance. Close off
the room to the rest of the house and open all windows. Keep the room well ventilated, as smoke
alarm may sound. Run the appliance for at least 6 hours at maximum setting to allow paint to cure.
Smoke and fumes caused by the curing process may cause discomfort to some individuals.
FIRST FIRE
1.
BEFORE LIGHTING,
smell all around the appliance area for gas. Be sure to smell next to the
floor, because some gasses are heavier than air and will settle on the floor.
2.
IF YOU SMELL GAS,
follow the instructions as listed directly above or as shown on the front
cover of this manual.
3.
Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
4.
This appliance is equipped with an ignition device which automatically lights the pilot and main
burner. The pilot and burner light automatically with the hand held remote or with the switch on
the side of the surround if it is activated.
W A R N I N G
This appliance needs fresh air for safe operation and must be installed so there are provisions for ade-
quate combustion and ventilation air.
A T T E N T I O N
If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life. Do not operate the appliance with the glass front re-
moved, cracked or broken. Replacement of broken glass should be done by a licensed or
qualified service person.
INITIAL OPERATION
1.
Check that the appliance is properly vented and connected to the gas supply.
2.
Check that all external parts, such as door and faceplate are properly attached and fastened.
3.
Do not operate this appliance with broken, cracked glass doors or without the door (s) in its correct (and
latched) position. Do not abuse the glass by either striking or slamming shut.
4.
Check that there are no fingerprints left on glass panels, as high temperature can bake these prints on
permanently.
FINAL INSTALLATION CHECK
Each Brigantia Fireplace is checked and tested at the factory prior to being packaged and shipped to our
dealers and finally installed in your home. Archgard recommends that before leaving this unit with the
customer, the installer must ensure that the appliance is firing
correctly and that the electrical system is in working order.
This will include:
1.
Perform leak tests of supply line, gas control valve, supply line from gas control valve and pilot assembly.
2.
Clocking the appliance to ensure the correct firing rate (see page 9 of this manual).
3.
If required, adjusting the primary air to burner to ensure that the flame does not carbon or soot.
4.
Check for proper operation including correct drafting.