brewer Flex 5700 Скачать руководство пользователя страница 11

Printed in USA © 2015 

11 

Document # 2102861 RevA

Brewer

FLEX

Access

Exam Table

Explosion/Fire Hazard

Do not use this table in an explosive or 

oxygen rich atmosphere. Failure to do so may 

result in serious personal injury or death.

Unintended Operation

Keep foreign objects away from foot control. To avoid 

accidental operation, be sure the foot control is NOT positioned 

below the front of the table. Failure to do so could result in 

unwanted motion, injury and possible damage to the table.

CAUTION

OPERATION

WARNING

Explosion/Fire Hazard

Do not use this table in an explosive or oxy-

gen rich atmosphere. Failure to do so may 

result in serious personal injury or death.

WARNING

Area Not Clear Hazard

Before initiating power keep personnel and equipment clear 

of table before initiating movement to avoid personal injury or 

damage to the equipment.

Avoid Foot Control Damage

The foot control is moisture resistant and runs on low voltage, 

eliminating shock hazards. However, to avoid temporary or 

permanent damage to the foot control, do not immerse in water 

or liquids.

NOTICE

Optimum Table Performance

For optimum table performance, allow the table to reach room 

temperature before operating.

NOTICE

Avoid Continuous Operation

The table’s control system includes a thermal overload safety 

switch to protect from overheating. If the table is operated 

continuously causing the control to exceed its allowable 

operating temperature, the thermal overload safety switch 

will shut off. If normal operation ceases, do not attempt to 

operate the table. Allow the table to cool for 10-15 minutes 

before attempting to use again. The thermal overload switch 

will automatically reset when it has reached a safe operating 

temperature. 

NOTICE

Fuse Protected

The control system is protected by a fuse to prevent excessive 

current draw which could damage the system. If operation does 

not resume after a cooling period of one hour, contact Brewer 

800-558-8777.

NOTICE

Actuator Travel Limit Protection

Each control function will automatically stop moving when 

either the UP or DOWN travel limit is reached. If the foot pedal 

is pressed with travel at its limit, the actuator will not operate. 

Sensors prevent the actuator motor from operating when travel 

limit has been reached, preventing wear of the actuator.

NOTICE

WARNING

Table Malfunction Hazard

If table malfunctions, immediately remove your foot from the 

controls, unplug the power cord from the receptacle, and 

assist the patient from the table. Service the table prior to use. 

Continuing to use a malfunctioning table may result in patient 

or personal injury, or product damage.

Proper Power Supply

Do not use any power supply other than that listed on the rating 

label. Failure to do so may result in equipment damage.

NOTICE

WARNING

WARNING

Shock Hazard

When performing cauterization or similar 

treatment, the patient must be insulated from 

the metal portions of the table by non-con-

ductive material. Failure to do so may result 

in electrical shock.

Содержание Flex 5700

Страница 1: ...Falls WI 53051 P 1 888 Brewer 1 F 262 251 2332 www brewercompany com Important Information 2 Safety Information 3 Component Identification 3 Specifications 4 Installation 5 Operation 11 Table Adjustme...

Страница 2: ...s primarily used in examination rooms for general examinations and minor procedures The wide variety of positions provided by one or two powered motions and slide out leg support create a safe and con...

Страница 3: ...e attempting to install or operate the unit Ensure that appropriate personnel are informed on the manual contents This is the responsibility of the purchaser Ensure that this manual is located near th...

Страница 4: ...in to 37 1 0 in Pelvic Tilt Range Models 5701 5801 Only 0 horizontal to 5 up Upholstery Dimensions Upholstered Top 24 to 28 in wide x 60 in long Upholstered Leg Support 18 in long x 18 in wide Overall...

Страница 5: ...ed 3 Remove the 2 screws attaching the spacers on either side of the wooden U shaped brace located under the front corners of the cabinet Figure 3 Remove the 2 screws attaching the U shaped brace to t...

Страница 6: ...eated Figure 6 8 Remove the gray power cord from the front drawer 9 Plug the power cord into the receptacle at the bottom of the rear panel Figure 5 Plug the power cord into a 115 Volt grounded recept...

Страница 7: ...niques Failure to do so could result in serious injury WARNING Avoid Stirrup Damage Do not lift or move table by using the stirrups as a hand hold Lifting or moving table by stirrups can damage the in...

Страница 8: ...Control and Power Cords Figure 13 Installing Leveler Slides 12 Raise the backrest to its full up position Figure 11 13 Unplug foot control and power cord and place into front storage drawer Figure 12...

Страница 9: ...loor Figure 16 1 Loosen the two Rear Base Extension adjusting screws 2 Lower plate until it contacts the floor 3 Tighten the two Rear Base Extension adjusting screws Figure 15 Leveling Screw Pad locat...

Страница 10: ...n until it engages to prevent left or right movement Grab Bar Pin Mounting Support Power Cord Inlet Foot Control Receptacle Installing the Power Cord 1 Remove the power cord from the front drawer 2 In...

Страница 11: ...s allowable operating temperature the thermal overload safety switch will shut off If normal operation ceases do not attempt to operate the table Allow the table to cool for 10 15 minutes before attem...

Страница 12: ...lowering of the seat and the raising and lowering of the seat back In addition the foot control features the following Return to Chair When pressed the table automatically returns to the low chair pos...

Страница 13: ...When clear of the switch continue lowering the seat Models 5800 5801 Depress the BACK UP pedal Figure 21 to clear the switch When clear of the switch continue lowering the seat OPERATION continued Sa...

Страница 14: ...the leg support pad for use during examination Pull the leg support fully out and remove the leg support pad or slide it back under the seat Figure 26 to access the pan Figure 26 Remove the treatment...

Страница 15: ...white plastic stop screw 2 Remove the white plastic screw Figure 30 3 Pull the work surface toward you and remove it 4 Reinsert screw after replacing work surface Figure 30 Location of White Plastic S...

Страница 16: ...e is normal and is part of the stirrup friction locking mechanism 2 Unfold stirrup upward to the fully open position 3 Adjust the stirrup to the desired length by sliding it in or out Stirrup Lateral...

Страница 17: ...p on the grab bar rotating it to the 90 position and then lifting it out of it s holder Table Height The table can be adjusted to any height between 18 to 37 Figure 36 1 To raise the table depress and...

Страница 18: ...from rising rapidly while pulling the release handle upward The seat back will lock in the desired position when the handle is released Powered Backrest Models 5800 5801 1 To lower the seat back depre...

Страница 19: ...5801 Models 5701 and 5801 are equipped with an Outlet Figure 40 The maximum total load that can be plugged into the outlet is 2 amps Figure 39 Front Drawer Warmer Switch Figure 40 Table Outlet Loweri...

Страница 20: ...nsure satisfac tory operation Check fasteners to make sure they are present and tightened securely Lubricate the backrest hinge with a food grade silicon lubricant Figure 41 Cover surrounding area wit...

Страница 21: ...ure 44 3 Locate fuse cover on control box See Figure 45 4 Pull out fuse cover with pliers 5 Replace fuses using spare fuses in fuse cover Fuse type is 250V 2 5AT for 115 VAC 6 Reassemble 1 Remove the...

Страница 22: ...led 100550 Provides attachment point for Knee Crutch Clamps Knee Crutch Clamp 99502 To hold deluxe articulating knee crutches 1 clamp only Pass Through Work Surface Field Installed 2102896 Contains Wo...

Страница 23: ...port Contains screws magnet tension springs etcetera Leg Support Pad 2102776 Replacement upholstered leg support pad Pass Through Work Surface Factory Installed 2102892 Contains Work Surface and hardw...

Отзывы: