Printed in USA © 2015
11
Document # 2102861 RevA
Brewer
FLEX
Access
Exam Table
Explosion/Fire Hazard
Do not use this table in an explosive or
oxygen rich atmosphere. Failure to do so may
result in serious personal injury or death.
Unintended Operation
Keep foreign objects away from foot control. To avoid
accidental operation, be sure the foot control is NOT positioned
below the front of the table. Failure to do so could result in
unwanted motion, injury and possible damage to the table.
CAUTION
OPERATION
WARNING
Explosion/Fire Hazard
Do not use this table in an explosive or oxy-
gen rich atmosphere. Failure to do so may
result in serious personal injury or death.
WARNING
Area Not Clear Hazard
Before initiating power keep personnel and equipment clear
of table before initiating movement to avoid personal injury or
damage to the equipment.
Avoid Foot Control Damage
The foot control is moisture resistant and runs on low voltage,
eliminating shock hazards. However, to avoid temporary or
permanent damage to the foot control, do not immerse in water
or liquids.
NOTICE
Optimum Table Performance
For optimum table performance, allow the table to reach room
temperature before operating.
NOTICE
Avoid Continuous Operation
The table’s control system includes a thermal overload safety
switch to protect from overheating. If the table is operated
continuously causing the control to exceed its allowable
operating temperature, the thermal overload safety switch
will shut off. If normal operation ceases, do not attempt to
operate the table. Allow the table to cool for 10-15 minutes
before attempting to use again. The thermal overload switch
will automatically reset when it has reached a safe operating
temperature.
NOTICE
Fuse Protected
The control system is protected by a fuse to prevent excessive
current draw which could damage the system. If operation does
not resume after a cooling period of one hour, contact Brewer
800-558-8777.
NOTICE
Actuator Travel Limit Protection
Each control function will automatically stop moving when
either the UP or DOWN travel limit is reached. If the foot pedal
is pressed with travel at its limit, the actuator will not operate.
Sensors prevent the actuator motor from operating when travel
limit has been reached, preventing wear of the actuator.
NOTICE
WARNING
Table Malfunction Hazard
If table malfunctions, immediately remove your foot from the
controls, unplug the power cord from the receptacle, and
assist the patient from the table. Service the table prior to use.
Continuing to use a malfunctioning table may result in patient
or personal injury, or product damage.
Proper Power Supply
Do not use any power supply other than that listed on the rating
label. Failure to do so may result in equipment damage.
NOTICE
WARNING
WARNING
Shock Hazard
When performing cauterization or similar
treatment, the patient must be insulated from
the metal portions of the table by non-con-
ductive material. Failure to do so may result
in electrical shock.