-32-
BURNER AND PILOT SYSTEM
The burner assembly may be removed for easier access to the control compartment.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Vacuum all components of the burner system.
• Visually check burner ports for blockage, especially near the pilot.
•
Visually check pilot light and burner flame pattern when in operation. Flames should be steady, not lifting or
floating.
FAN
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Disconnect the fans from electrical current and vacuum.
• The bearings are sealed and require no oiling.
VENT SYSTEM
NOTE: If the vent-air intake system is disassembled for any reason, reinstall per instructions provided with installation
(see Installation section).
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Examination of the vent system is required.
•
The flow of combustion and ventilation air must not be obstructed.
Burner
Orifice
Breakout View
For Clarification
Purposes Only
Burner Ports
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
WARNING: The fireplace area must be kept clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
Содержание BH6113LFP