In BMI Mode
6.3.3 Parameter EH-SCP (PS-60)
Set the USER-COM1/2-LAYOUT parameter to
eh-scp
This protocol is compatible with Toledo PS60 protocol. The baud rate and data format
is set by User menu.
Output Status Bit Meaning
Table 6.4 Status Bits
DATE
2014-12-29
TIME
12:34:56
A/D CODE:
1234345
VOLTAGE:
6.7V
STATUS:
bpq2
SCALE ID:
123456
GROSS:
110.0kg
TARE:
10.0kg
NET:
100.0kg
HEIGHT
170cm
BMI
34.6
DATE
2014-12-29
TIME
12:34:56
A/D CODE:
1234567
VOLTAGE:
6.7V
STATUS:
bpq2
Bit
Status
0
0 = not in motion
1 = in motion
1
0 = not over capacity
1 = over capacity
2
0 = not under zero (positive polarity)
1 = under zero (negative polarity)
3
0 = inside zero capture range
1 = outside zero capture range
4
0 = not center of zero
1 = center of zero
5
always 1
6
always 1
7
parity