Table 6.2 Bit Definition of H
1
H
2
H
3
H
4
W
1
---W
6
Reading data, 1-6 bytes (six digits)
<DP>
Decimal point
U
1
U
2
U
3
U
4
U
5
Measure units, kg, lb, lb:oz, % or pcs; 2-5 bytes
<Add>
Address of scale; 2 bytes (00-99)
<Prompt>
Prompt characters of output content; max. 11bytes
Bit
Byte 1 (H
1
)
Byte 2 (H
2
)
Byte 3 (H
3
)
Byte 4 (H
4
)
0
0 = stable
0 = not under capacity 00 = compare disable
01 = lower limit
10 = ok
11= upper limit
00 = normal weighing
01 = count weighing
10 = percent weighing
11 = other mode
1 = not stable
1 = under capacity
1
0 = not at zero point 0 = not over capacity
1 = at zero point
1 = over capacity
2
0 = RAM ok
0 = ROM ok
0 = gross weight
0 = not in HOLD
1 = RAM error
1 = ROM error
1 = net weight
1 = in HOLD
3
0 = eeprom OK
0 = calibration ok
0 = initial zero ok
0 = battery ok
1 = eeprom error
1 =calibration error
1 = initial zero error
1 = low battery
4
always 1
always 1
always 1
always 1
5
always 1
always 1
always 1
always 1
6
always 0
always 1
always 1
always 0
7
parity
Parity
parity
Parity
Содержание SBI-240
Страница 1: ...SBI 240 Weighing Indicator Service Manual AWT35 501 Issue AA ...
Страница 5: ...SBI 240 Service Manual 5 ...
Страница 7: ......
Страница 9: ...ti E ...
Страница 10: ......
Страница 34: ...TARE PRESET SBI 240 Service Manual ...
Страница 57: ...SBI 240 Service Manual 55 Table 5 1 Location Code For Elevation and Latitude ...
Страница 76: ...74 SBI 240 Service Manual ...
Страница 77: ......