![Brecknell SBI-240 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/brecknell/sbi-240/sbi-240_service-manual_2806415036.webp)
34
SB
I-240
Service Manual
PRIM.N
100 -
100000
Primary full scale valu
e D
efault full scale value will depend
on capacity of scale.
*
If (REGULA)
≠
none, the max is
10,000
PRIM.D
0.0001
The
division value under
primary unit
Default division size will depend on
capacity of scale.
The division value under second
unit is automatically determined by
the indicator according to the
division value under primary unit.
0.0002
0.0005
0.001
0.002
0.005
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
20
50
PRIM.Ut
kg
Primary u
Select the primary unit from kg or lb.
The second unit is lb if kg is
selected as the primary unit.
*
The calibration standard weight
must be in the primary unit!
lb
SECnD.N
100-
125000
Second scale full scale
value
The division number under second
unit. The maximum is
1.25*(PRIM.N).
*If (REGULA)
≠
none, the max is
10,000
NOTE: Secondary division has to
match the primary division.
CONFG
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment
Содержание SBI-240
Страница 1: ...SBI 240 Weighing Indicator Service Manual AWT35 501 Issue AA ...
Страница 5: ...SBI 240 Service Manual 5 ...
Страница 7: ......
Страница 9: ...ti E ...
Страница 10: ......
Страница 34: ...TARE PRESET SBI 240 Service Manual ...
Страница 57: ...SBI 240 Service Manual 55 Table 5 1 Location Code For Elevation and Latitude ...
Страница 76: ...74 SBI 240 Service Manual ...
Страница 77: ......